Skip to main content
Siemens 3RU2146-4MB1 — Overload Relays

Siemens 3RU2146-4MB1 SIRIUS Thermal Overload Relay, Size S3,

MPN3RU2146-4MB1
Active

Siemens SIRIUS thermal overload relay, 3RU2146-4MB1, Size S3, Trip Class 10, 690 V rated, 45 kW at 400 V, screw-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RU2146-4MB1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S3
Combinable contactor sizesS3
Reference code (IEC 81346-2)F
3RU2146-4MB1 — Protection & Trip
ParameterValue
Overload current setting range80 ... 100 A
Trip classCLASS 10
Overload release typethermal
3RU2146-4MB1 — Electrical (main circuit)
ParameterValue
Rated operational current100 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)1 000 V
Rated value (AC-3e), max.1 000 V
Rated surge withstand voltage8 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)21 W
Per pole7 W
3RU2146-4MB1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2146-4MB1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (2.5 ... 16 mm²)
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (10 ... 1/0), 1x (10 ... 2/0)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2146-4MB1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2146-4MB1 — Mechanical
ParameterValue
Width70 mm
Height120 mm
Depth140 mm

Product details

SIRIUS 3RU2146-4MB1 — Thermal Overload Relay, Size S3, Class 10

The Siemens 3RU2146-4MB1 is a SIRIUS-brand thermal overload relay, Size S3, Trip Class 10. Rated for main circuit voltages up to 690 V, the relay handles 45 kW at 400 V (AC-3e duty) and 90 kW at 690 V. The size S3 frame and screw-type terminals accept solid conductors up to 16 mm² and stranded up to 70 mm², suiting it for motor branch circuits in the 30–100 A range. Mount in any position on a flat panel or DIN rail via stand-alone installation. The relay includes a trip-indicator flag and a "Tripped" message contact for remote signaling — useful for a PLC or HMI to log the fault without sending someone to the cabinet.

Current Production — Sourcing This Part

Substance prohibitance per RoHS is recorded with a date of 03/01/2017, confirming compliance with the EU RoHS directive.

Auxiliary Contact Ratings and Wiring

The auxiliary contact block carries 2 A at 24 V, 3 A at 120 V, and 0.75 A at 690 V — enough to drive a PLC input or a small contactor coil directly. At 24 VDC the 2 A rating is the limiting case for inductive loads; verify the inrush of the driven device stays under that. Terminals accept solid 2x (0.5–1.5 mm²) or stranded 2x (0.75–2.5 mm²) for the control circuit. Main circuit terminals use M8 bolts with a 4 mm hex socket driver.

Temperature Compensation and Environmental Range

The relay compensates for ambient temperature changes across -40 to +60 °C, maintaining accurate trip timing without manual adjustment. Power dissipation per pole is 7 W at rated current — account for this heat in a densely packed enclosure to avoid derating adjacent devices.

Frequently asked questions

What does the 'Note for message Tripped' mean on 3RU2146-4MB1?

The relay provides a dedicated signaling contact that changes state when the overload trips, outputting a 'Tripped' message. This can be wired to a PLC digital input or an HMI alarm annunciator for remote fault indication.

What is the depth of 3RU2146-4MB1?

The depth is 140 mm. Overall dimensions are 70 mm wide by 120 mm tall by 140 mm deep, fitting a standard Size S3 panel footprint.

What compliance documentation does Siemens provide for 3RU2146-4MB1?

The relay carries RoHS compliance with a substance prohibitance date of 03/01/2017. Standard Siemens documentation includes the datasheet, operating instructions, and a CE declaration of conformity. UL and CSA approvals are typical for SIRIUS overload relays but are not explicitly listed in this record.

MPN
3RU2146-4MB1