Skip to main content
Siemens 3RU2916-3AC01 — Overload Relays

Siemens 3RU2916-3AC01 SIRIUS Overload Relay, Size S00

MPN3RU2916-3AC01
Active

Siemens SIRIUS 3RU2916-3AC01 overload relay, Size S00, individual mount, spring-loaded terminals for main circuit, 45 mm width, 102 mm height, 68 mm depth.

$5.49Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RU2916-3AC01 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationindividual mount
Frame size (overload relay)S00
3RU2916-3AC01 — Electrical (main circuit)
ParameterValue
Main current circuitspring-loaded terminals
3RU2916-3AC01 — Connection & Mounting
ParameterValue
Mounting / fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Conductor cross-section: solid1x (0.5 ... 4 mm²)
Conductor cross-section: finely stranded with ferrule0.5 ... 2.5 mm²
3RU2916-3AC01 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-50 ... +80 °C
3RU2916-3AC01 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth68 mm
3RU2916-3AC01 — Other specifications
ParameterValue
Stranded1x (0,5 ... 4 mm²)
Substance prohibitance10/01/2009
For AWG cables for main contacts1x (20 ... 12)

Product details

SIRIUS Size S00 overload relay — spring terminals, DIN-rail mount

The 3RU2916-3AC01 is a Siemens SIRIUS overload relay in the Size S00 frame, designed for individual (stand-alone) mounting. It provides motor protection for the 3RU21, 3RB30, 3RB31, and 3RR2 relay families in the same size class. Fastening is by screw or snap-on onto 35 mm DIN rail, which means it integrates into standard control panels without special adapters.

Terminal wiring — spring-loaded main circuit

The main current circuit uses spring-loaded terminals, accepting 1x solid wire from 0.5 to 4 mm² (20 to 12 AWG) and 1x stranded wire from 0.5 to 4 mm². Finely stranded wire with core end processing is supported from 0.5 to 2.5 mm². No auxiliary circuit terminals are fitted on this variant — the auxiliary circuit connection is listed as '--' in the specification.

Environmental limits and compliance

Operating temperature range is -20 to +70 °C; storage range is -50 to +80 °C. The substance prohibitance date is 10/01/2009, indicating RoHS compliance from that date.

Frequently asked questions

What is the physical size of 3RU2916-3AC01 for panel layout?

Width is 45 mm, height is 102 mm, depth is 68 mm. This is the Size S00 footprint, which fits the standard 35 mm DIN-rail mounting pattern.

What wire sizes does the spring terminal accept?

Solid wire: 1x (0.5 to 4 mm²) or 20 to 12 AWG. Stranded wire: 1x (0.5 to 4 mm²). Finely stranded with ferrule: 0.5 to 2.5 mm².

MPN