Skip to main content
Siemens 3RU5136-4DB0 — Overload Relays

Siemens 3RU5136-4DB0 SIRIUS Thermal Overload Relay, 18-25 A,

MPN3RU5136-4DB0

Siemens SIRIUS thermal overload relay, 3RU5136-4DB0, 18-25 A adjustable, CLASS 10, 690 V, 50-60 Hz, screw terminals, contactor mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RU5136-4DB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationThermal overload relay
Combinable contactor sizesS2
3RU5136-4DB0 — Protection & Trip
ParameterValue
Overload current setting range18 ... 25 A
Trip classCLASS 10
Overload release typethermal
3RU5136-4DB0 — Electrical (main circuit)
ParameterValue
Rated operational current25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)10.5 W
Per pole3.5 W
3RU5136-4DB0 — Auxiliary contacts
ParameterValue
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 230 V2 A
3RU5136-4DB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RU5136-4DB0 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating0 ... 100 %
Max. installation altitude2 000 m
3RU5136-4DB0 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth118 mm

Product details

Its adjustable current response range is 18 to 25 A, and it's rated for a rated operational current of 25 A at 690 V, 50-60 Hz. It mounts directly onto a SIRIUS S2-size contactor (company-specific combination size S2), so it's a matched set with the contactor — no separate bracket or wiring harness needed for the power circuit.

Mounting is via contactor mounting — it snaps onto the SIRIUS S2 contactor. The mounting position allows a vertical mounting surface with ±135° rotation and ±45° tilt front-to-back, giving flexibility in tight panels. Dimensions: 105 mm high, 55 mm wide, 118 mm deep. The width is the key panel-space number — at 55 mm, it's a single-unit-wide footprint on the DIN rail when combined with its contactor. Requires 6 mm spacing to grounded parts at the side for proper heat dissipation and clearance.

Main circuit terminals are screw-type, top and bottom, accepting 2×(0.5-1.5 mm²) solid/stranded or 2×(0.75-2.5 mm²) finely stranded with ferrules, or AWG 2×(18-3) and 1×(18-1). Tightening torque is 3-5 N·m. Auxiliary/control circuit terminals are also screw-type, accepting 2×(20-16) AWG or 2×(18-14) AWG. For short-circuit protection of the auxiliary switch, use a gL/gG 6 A fuse or a quick-acting 10 A fuse.

Relative humidity from 0 to 100% is allowed during operation — no derating needed for high-humidity environments. Shock resistance per IEC 60068-2-27 is 8g for 10 ms. Installation altitude is limited to 2000 m above sea level without derating. RoHS compliance date is July 1, 2006 — the part meets the original RoHS directive. Surge voltage resistance is 6 kV, and insulation voltage at pollution degree 3 is 690 V AC.

Frequently asked questions

What is the adjustable current range of the 3RU5136-4DB0?

The adjustable current response range is 18 to 25 A, with a rated operational current of 25 A.

What trip class is the 3RU5136-4DB0?

It is CLASS 10, meaning it trips within 10 seconds at 7.2× the set current — suitable for standard motor protection.

What contactor does the 3RU5136-4DB0 mount to?

It mounts directly onto a SIRIUS S2-size contactor (company-specific combination size S2) via contactor mounting — no separate bracket needed.

What compliance documentation does the 3RU5136-4DB0 have?

RoHS compliance date is July 1, 2006. The part also carries rated surge voltage resistance of 6 kV and insulation voltage of 690 V AC at pollution degree 3.

MPN
3RU5136-4DB0