Siemens 3RU5136-4EB0 — Overload Relays

Siemens 3RU5136-4EB0 SIRIUS Thermal Overload Relay, 22-32 A,

MPN3RU5136-4EB0

Siemens SIRIUS 3RU5136-4EB0 thermal overload relay, adjustable 22-32 A, Trip Class 10, 690 V rated voltage, screw terminals, contactor mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RU5136-4EB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationThermal overload relay
Combinable contactor sizesS2
3RU5136-4EB0 — Protection & Trip
ParameterValue
Overload current setting range22 ... 32 A
Trip classCLASS 10
Overload release typethermal
3RU5136-4EB0 — Electrical (main circuit)
ParameterValue
Rated operational current32 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)13.8 W
Per pole4.6 W
3RU5136-4EB0 — Auxiliary contacts
ParameterValue
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 230 V2 A
3RU5136-4EB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 3), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU5136-4EB0 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating0 ... 100 %
Max. installation altitude2 000 m
3RU5136-4EB0 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth118 mm

Product details

Thermal overload relay for S2 contactors

The Siemens 3RU5136-4EB0 is a SIRIUS thermal overload relay with an adjustable current response range of 22 to 32 A, Trip Class 10, and a rated operational current of 32 A at 690 V. It mounts directly onto S2-size contactors (Siemens SIRIUS series) via the contactor-mounting fastening method, saving DIN-rail space and reducing wiring. The 3-pole design uses screw-type terminals for both main and auxiliary circuits, accepting solid or stranded wire up to 2x (0.75... 2.5 mm²) for the main circuit and 2x (20... 16) AWG for auxiliary contacts.

The adjustable overload release (22-32 A) lets you dial in the exact motor FLA without swapping parts — set it to the motor nameplate current. The 50/60 Hz operating frequency means it works on either line frequency. The 6 kV surge voltage resistance (rated) ensures the relay holds up to transients common in industrial panels.

Mounts directly to S2 contactors (Siemens SIRIUS series) — no DIN rail required for the relay itself, though the contactor may be DIN-rail or panel-mounted. The mounting position allows vertical surface mounting with ±135° rotation and ±45° tilt front/back, giving flexibility in tight enclosures. Dimensions: 118 mm deep, 55 mm wide, 105 mm high. Side spacing to grounded parts: 6 mm minimum. Terminal torque for main contacts: 3-5 N·m. Ambient operating temperature: -20 to +70 °C; storage/transport: -55 to +80 °C. Relative humidity 0-100% permissible during operation.

The relay carries a substance prohibition date of 07/01/2006 (RoHS compliance reference). Shock resistance per IEC 60068-2-27: 8g / 10 ms. Insulation voltage 690 V AC at pollution degree 3. Short-circuit protection for the auxiliary switch: fuse gL/gG 6 A or quick 10 A. The product is part of the Siemens SIRIUS family, which holds UL, CSA, CE, and other international approvals (not individually listed in this record, but standard for the series).

Frequently asked questions

What is the adjustable current range of 3RU5136-4EB0?

The adjustable current response value is 22 to 32 A. Set it via the dial on the front of the relay to match the motor full-load current.

What Trip Class is 3RU5136-4EB0?

Trip Class 10 — it will trip within 10 seconds at 7.2× the current setting, suitable for standard induction motor starting.

Will 3RU5136-4EB0 fit a panel designed for 3RT5034-1BW40?

The 3RU5136-4EB0 mounts to S2 contactors; the 3RT5034-1BW40 is a different contactor frame. The relay will not physically drop into a panel wired for that contactor without adapting the mounting and wiring. Verify the contactor size in the existing panel before ordering.

Where can I buy 3RU5136-4EB0?

Sourced to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RU5136-4EB0