Skip to main content
Siemens 3RV1011-0AA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0AA10-ZI45 SIRIUS Motor Protection Circuit B

MPN3RV1011-0AA10-ZI45

Siemens SIRIUS motor protection circuit breaker, size S00, CLASS 10, adjustable overload release 0.11…0.16 A, screw terminals, standard switching capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0AA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0AA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0AA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-0AA10-ZI45 — Connections
ParameterValue
Main-circuit connector arrangementTop and bottom
3RV1011-0AA10-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-0AA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The adjustable overload release covers 0.11 to 0.16 A, and the trip class is CLASS 10, meaning it will trip within 10 seconds at 7.2× the set current — fast enough to protect a standard induction motor winding from sustained overload without nuisance tripping on start-up transients. The magnetic short-circuit trip responds at a fixed multiple of the overload setting, clearing hard faults before the contactor welds.

The S00 footprint — 45 mm wide, 90 mm high, 75 mm deep — fits standard motor control centre buckets and small panel layouts. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the side, zero forwards and backwards. That zero forward/backward clearance means no extra breathing space is needed behind or in front of the breaker face, which simplifies panel layout when the breaker sits against a gland plate or back panel.

Frequently asked questions

What is the adjustable overload range for 3RV1011-0AA10-ZI45?

The current-dependent overload release is adjustable from 0.11 to 0.16 A. This range lets you fine-tune the trip point to match the full-load amperage of the protected motor, provided the motor FLA falls within that window.

Will 3RV1011-0AA10-ZI45 drop into a panel specified around 3RV1011-0GA10?

Both are S00 frame size with the same mounting method and identical clearance requirements (20 mm up/down, 9 mm side, zero front/back). The physical footprint and DIN-rail clip are the same, so no panel rework is needed. The difference is the overload range: the 0GA10 covers 0.45–0.63 A, while this -ZI45 covers 0.11–0.16 A. Provided the motor FLA matches the lower range, the swap is a straight mechanical drop-in.

How do I get current pricing and availability for 3RV1011-0AA10-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation — submit an RFQ for a firm commercial offer.

MPN
3RV1011-0AA10-ZI45