Siemens 3RV1011-0AA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0AA10-ZW95 SIRIUS Motor Protection CB, Class

MPN3RV1011-0AA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0AA10-ZW95, Class 10 trip, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0AA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0AA10-ZW95 — Electrical
ParameterValue
Rated operational current (Ie)0.16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0AA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range0.11 ... 0.16 A
Instantaneous short-circuit trip current2.1 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0AA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0AA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0AA10-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0AA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0AA10-ZW95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

That's not a fast trip for short-circuit; that's the thermal overload curve protecting the motor windings.

Breaking capacity — what 100 kA means at 400 V

For a panel fed from a transformer with high fault potential, that rating keeps the arc flash contained within the breaker.

Mounting position is any — vertical, horizontal, upside-down — which simplifies panel layout when you're stacking breakers in a tight enclosure. Screw terminals accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded, so common motor feeder cables land without adapters. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the sides, zero forwards and backwards. That means it can sit flush against a backplate or gland plate without derating.

Frequently asked questions

Will 3RV1011-0AA10-ZW95 drop into a panel built for 3RV1011-0GA10 without rewiring?

Yes — same 45 mm width, same DIN rail mounting, same screw terminal arrangement. The -ZW95 variant carries a different order-code suffix but shares the physical footprint and terminal layout of the 3RV1011-0GA10.

MPN
3RV1011-0AA10-ZW95