Siemens SIRIUS motor-protective circuit breaker, 3RV1011-0AA10-ZX95, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw-type terminals, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0AA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0AA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0AA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.11 ... 0.16 A
Instantaneous short-circuit trip current2.1 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0AA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0AA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0AA10-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0AA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0AA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

SIRIUS 3RV1011-0AA10-ZX95 — motor-protective circuit breaker, Class 10

That means it fits standard enclosures without special brackets — a straight swap into existing motor starter assemblies.

The 100 kA breaking capacity at 400 V (and at 240 V, 500 V, 690 V) means this breaker can safely interrupt a fault current up to 100 kA without upstream fuses or a larger frame — critical for high-capacity MCCs or distribution near transformers. Phase-failure detection adds protection against single-phasing on three-phase loads. Screw-type terminals accept 2x (0.5–1.5 mm²) or 2x (0.75–2.5 mm²) solid or stranded — no special crimp tools needed for field wiring.

Panel integration — footprint and clearances

Dimensions: 45 mm wide, 90 mm high, 75 mm deep. Side clearance to adjacent devices is 9 mm; top clearance 20 mm; bottom clearance 20 mm; no clearance needed forward or backward. That fits standard 45 mm modular spacing on DIN rail — no surprises in a crowded cabinet.

Frequently asked questions

What is the depth and width of 3RV1011-0AA10-ZX95?

Depth is 75 mm, width is 45 mm, height is 90 mm.