Skip to main content
Siemens 3RV1011-0BA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0BA10-ZW97 SIRIUS Motor Circuit Breaker, Cla

MPN3RV1011-0BA10-ZW97
Active

Siemens SIRIUS, motor-protective circuit breaker, 3RV1011-0BA10-ZW97, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV1011-0BA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0BA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0BA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.14 ... 0.2 A
Instantaneous short-circuit trip current2.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0BA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0BA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0BA10-ZW97 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0BA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0BA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV1011-0BA10-ZW97 is a motor-protective circuit breaker designed for motor protection, with a Class 10 trip characteristic and a 100 kA breaking capacity at 400 V AC. It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, fitting standard panel layouts.

What the ratings mean for your panel

The 100 kA breaking capacity at 400 V AC means this breaker can safely interrupt fault currents up to that level without upstream devices needing to clear the fault — critical for high-fault panels near large transformers. The Class 10 trip clears overloads within 10 seconds at 7.2× rated current, matching standard motor start profiles for pumps and conveyors. Phase failure detection is built in, so a lost phase on the line side trips the breaker rather than letting the motor single-phase and burn.

Mounting and integration

Screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Mounting position any. Clearance: 20 mm upwards, 20 mm downwards, 9 mm at the side. Forwards and backwards zero clearance. Screw-type terminals for the main current circuit; terminal capacity 2x (0.5...1.5 mm²) or 2x (0.75...2.5 mm²) solid or stranded. Main contact screw size M3.

Frequently asked questions

Where can I buy 3RV1011-0BA10-ZW97?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV1011-0BA10-ZW97 at 400 V?

100 kA at 400 V AC.

Does 3RV1011-0BA10-ZW97 include phase failure protection?

Yes, phase failure detection is built in.

What are the mounting clearances for 3RV1011-0BA10-ZW97?

20 mm upwards, 20 mm downwards, 9 mm at the side. Zero clearance forwards and backwards.

MPN
3RV1011-0BA10-ZW97