Skip to main content
Siemens 3RV1011-0BA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0BA25 SIRIUS Motor Circuit Breaker, 0.2 A, C

MPN3RV1011-0BA25

Siemens SIRIUS 3RV1011-0BA25 motor-protective circuit breaker, 0.2 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0BA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-0BA25 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0BA25 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-0BA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-0BA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)

Mechanical

3RV1011-0BA25 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-0BA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-0BA25 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What it is and what it does

The Siemens 3RV1011-0BA25 is a SIRIUS motor-protective circuit breaker, designed to protect motor circuits against overload and short-circuit. Its 0.2 A continuous current rating and CLASS 10 trip class mean it's sized for small fractional-horsepower motors — the CLASS 10 trip curve clears an overload within 10 seconds at 7.2× rated current, matching the thermal time constant of a standard induction motor. It carries a 100 kA breaking capacity across the full AC voltage range (240 V through 690 V), so it can safely interrupt high-fault currents without upstream fuses in most panel designs. Phase failure detection is built in — if one phase drops, the breaker trips, preventing single-phasing damage to the motor.

Panel integration and mounting

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 50022. The 45 mm width and 90 mm height fit a standard 4-module footprint; depth is 81 mm, which clears most shallow enclosures. Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or stranded wire — no lug torque check needed, just strip and push. IP20 on the front face means it's protected against finger contact but not washdown — keep it inside a closed panel. Any mounting position is allowed, which helps when you're cramming gear into a tight gland plate layout.

Frequently asked questions

What is the breaking capacity of the 3RV1011-0BA25?

100 kA at AC 240 V, 400 V, 500 V, and 690 V — that's a single rating across the board, not derated at higher voltages.

What wire size does the 3RV1011-0BA25 accept on the main terminals?

Spring-loaded terminals accept 2x (0.25... 2.5 mm²) solid or stranded, or 2x (24... 14 AWG).

Does the 3RV1011-0BA25 detect phase failure?

Yes, phase failure detection is built in — it will trip if one phase drops out.

Where can I buy the 3RV1011-0BA25?

This part is available to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3RV1011-0BA25