Skip to main content
Siemens 3RV1011-0CA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0CA10-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1011-0CA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0CA10-ZW95, Trip Class 10, 100 kA breaking capacity at 400 V AC, phase failure detection, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0CA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0CA10-ZW95 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0CA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current3.3 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0CA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0CA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0CA10-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0CA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0CA10-ZW95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Dimensions are 45 mm wide, 90 mm high, and 75 mm deep. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the side, 0 mm forwards and backwards. This means it fits standard panel layouts with minimal spacing overhead — a direct drop-in for existing SIRIUS 3RV1 footprints.

Ratings and Protection

The 100 kA breaking capacity holds at 240 V, 400 V, 500 V, and 690 V AC, giving solid SCCR headroom for most industrial distribution panels.

Frequently asked questions

Where can I buy 3RV1011-0CA10-ZW95 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

Will 3RV1011-0CA10-ZW95 drop into a panel specified around 3RV1011-0GA10 without rewiring?

Both share the same SIRIUS 3RV1 footprint — 45 mm width, 90 mm height, 75 mm depth, and identical DIN-rail mounting with the same clearance requirements. The terminal arrangement (screw-type terminals for the main circuit) is consistent across the 3RV1011 family, so a direct mechanical and electrical swap is expected without rewiring.

What compliance documentation does this brand provide for 3RV1011-0CA10-ZW95?

As a Siemens SIRIUS product, standard documentation includes RoHS and REACH declarations, plus IEC/EN 60947-4-1 compliance for motor protection circuit breakers. The 100 kA breaking capacity ratings at 240 V through 690 V AC are per IEC 60947-2. Specific certificates (UL, CSA, CCC) should be verified against the nameplate variant code.

MPN
3RV1011-0CA10-ZW95