Siemens 3RV1011-0CA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0CA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1011-0CA20-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0CA20-ZX95, 0.25 A continuous current, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0CA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-0CA20-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0CA20-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-0CA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-0CA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-0CA20-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-0CA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-0CA20-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-0CA20-ZX95 is a SIRIUS motor-protection circuit breaker designed for 3-phase AC motors up to 0.06 kW at 400 V. Rated continuous current is 0.25 A, with a CLASS 10 trip characteristic — meaning it will trip within 10 seconds at 7.2× rated current, matching the thermal curve of standard squirrel-cage induction motors during start-up. Ground fault detection is not included — that requires a separate residual-current device or a different SIRIUS variant.

Main circuit terminals are spring-loaded, accepting 2x (0.25 to 2.5 mm²) solid or 2x (0.25 to 1.5 mm²) fine-stranded with ferrule. The auxiliary switch option allows a separate signal contact for remote status.

Shock resistance is 25g for 11 ms, and mechanical endurance of the main contacts is rated at 100,000 operations. Maximum switching frequency at AC-3 duty is 15 operations per hour.

Frequently asked questions

What terminals does this breaker use?

The main current circuit uses spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or 2x (0.25 to 1.5 mm²) fine-stranded with ferrule.

Will the 3RV1011-0CA20-ZX95 drop into a panel specified for the 3RV1011-0GA10?

Both are 45 mm wide SIRIUS motor-protection breakers with the same mounting rail and terminal style, so the mechanical fit is identical. The difference is the current rating and trip class — verify the 0.25 A / CLASS 10 combination matches your motor's full-load current and start profile before substituting.