Skip to main content
Siemens 3RV1011-0FA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0FA10-0FJ0-ZX95 SIRIUS Motor Protective Circ

MPN3RV1011-0FA10-0FJ0-ZX95

Siemens SIRIUS 3RV1011-0FA10-0FJ0-ZX95 motor-protective circuit breaker, 0.5 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0FA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-0FA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0FA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-0FA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-0FA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-0FA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-0FA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-0FA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1011-0FA10-0FJ0-ZX95 is a motor-protective circuit breaker rated at 0.5 A continuous current with CLASS 10 trip characteristics. It delivers 100 kA breaking capacity at 400 V AC, meaning it can safely interrupt fault currents up to that level without cascading upstream — critical for panel selectivity in high-fault installations. Phase failure detection is built in, so a lost phase trips the breaker before the motor burns. The 45 mm width and 81 mm depth fit standard DIN-rail enclosures; screw and snap-on mounting onto 35 mm rail per DIN EN 50022 simplifies panel integration.

Installation & Environment

Mount in any position on 35 mm DIN rail per DIN EN 50022. Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. IP20 on the front means the breaker is touch-safe but not sealed against moisture — suitable for dry indoor panels, not washdown zones. Shock-rated to 25g for 11 ms, so it holds up in applications with moderate vibration.

Termination & Wiring

Main circuit terminals are screw-type, accepting solid or stranded conductors: 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²), with AWG equivalents 2x (18 to 14). Finely stranded with core end processing uses the same ranges. No auxiliary contacts are included (0 for auxiliary contacts), but the breaker has an auxiliary switch option (yes).

Frequently asked questions

Where can I buy 3RV1011-0FA10-0FJ0-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this breaker at 400 V?

The rated breaking capacity at 400 V AC is 100 kA, meaning it safely interrupts fault currents up to that level without upstream damage.

Will 3RV1011-0FA10-0FJ0-ZX95 drop into a panel specified for 3RV1011-0GA10?

Both share the same SIRIUS family footprint — 45 mm width, 81 mm depth, screw and snap-on mounting on 35 mm DIN rail — so physical fit and rail mounting are identical. The difference is in the trip rating and breaking capacity; verify your load current against the 0.5 A continuous rating of this variant.

MPN
3RV1011-0FA10-0FJ0-ZX95