Skip to main content
Siemens 3RV1011-0HA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0HA10-ZI45 SIRIUS Motor Protection Circuit B

MPN3RV1011-0HA10-ZI45

Siemens SIRIUS motor protection circuit breaker, size S00, CLASS 10, adjustable overload release 0.55…0.8 A, magnetic short-circuit trip 10 A, screw-type terminals, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0HA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0HA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-0HA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1011-0HA10-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-0HA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection breaker for small loads

Rated operating current is 0.8 A at AC-3 duty (400 V), delivering 180 W of motor power at that voltage — sized for fractional-horsepower loads like small pumps, fans, and conveyors. The thermal overload release is field-adjustable from 0.55 A to 0.8 A, letting you dial in the exact FLA of the connected motor without swapping the breaker body.

Trip class and short-circuit protection

The magnetic short-circuit release is fixed at 10 A, providing instantaneous interruption for hard faults while letting the overload element handle sustained overcurrents.

Any mounting position is permitted. Clearance requirements: 20 mm upwards and downwards, 9 mm to the side, zero forwards and backwards. The 20 mm vertical gap is the minimum free air space needed above and below the breaker for arc quenching and heat dissipation.

Frequently asked questions

What are the clearance requirements for 3RV1011-0HA10-ZI45?

Requires 20 mm upwards, 20 mm downwards, and 9 mm to the side. Zero clearance needed forwards or backwards.

Will 3RV1011-0HA10-ZI45 drop into a panel specified for 3RV1011-0HA10?

Yes. The -ZI45 variant shares the same S00 frame, DIN rail mounting, screw terminals, and 45×90×75 mm footprint as the base 3RV1011-0HA10. No rewiring or panel modification needed.

MPN