Skip to main content
Siemens 3RV1011-0HA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0HA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1011-0HA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0HA10-ZW97, Class 10, 100 kA breaking capacity at 400 V AC, screw terminals, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0HA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-0HA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0HA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-0HA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-0HA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-0HA10-ZW97 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-0HA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-0HA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens 3RV1011-0HA10-ZW97 is a SIRIUS motor protection circuit breaker designed for motor protection in control panels. It combines a circuit breaker and overload relay in one device, with a Trip Class 10 characteristic that matches standard motor starting curves — meaning it allows the inrush during start but trips fast enough to protect the motor winding from sustained overload. Rated breaking capacity hits 100 kA at 400 V AC, so it can safely interrupt high fault currents without needing an upstream fuse for most industrial distribution panels. Phase failure detection is built in, which is critical for three-phase motor protection — if one phase drops, the breaker trips before single-phasing damages the motor.

Mounting and integration

Clearance distances: 20 mm upwards and downwards, 9 mm at the side, 0 mm forwards and backwards — tight enough for dense panel layouts but leave that 20 mm top/bottom for arc chute venting.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-0HA10-ZW97?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

Will 3RV1011-0HA10-ZW97 drop into a panel that was specified around 3RV1011-0HA10 without rewiring?

Yes. The -ZW97 suffix indicates a special variant, but the base model 3RV1011-0HA10 shares the same footprint, terminal layout, and trip characteristics. No rewiring or panel modification is needed.

MPN
3RV1011-0HA10-ZW97