Skip to main content
Siemens 3RV1011-0HA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0HA10-ZX95 SIRIUS Motor Protection Breaker,

MPN3RV1011-0HA10-ZX95
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV1011-0HA10-ZX95, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 x 90 x 75 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0HA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-0HA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0HA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-0HA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-0HA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-0HA10-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-0HA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-0HA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

SIRIUS motor protection circuit breaker — 3RV1011-0HA10-ZX95

The Siemens SIRIUS 3RV1011-0HA10-ZX95 is a motor protection circuit breaker designed to protect three-phase motors against overload and short-circuit faults. It is part of the SIRIUS family, a modular system for motor feeders and control circuits. Rated Trip Class 10, meaning it will trip within 10 seconds at 7.2x the thermal setting — standard protection for standard induction motors starting under load, like pumps and conveyors. Breaking capacity rated 100 kA at 400 V AC — that's the maximum fault current it can safely interrupt without welding contacts or rupturing the case. Same rating holds at 240 V, 500 V, and 690 V. For a panel with high available fault current, this breaker holds the line without needing an upstream current-limiting fuse in most cases. Includes phase failure detection — if one phase drops out, the breaker trips faster than a standard thermal overload, preventing single-phasing damage to the motor winding.

Mounting and integration

Snaps onto 35 mm DIN rail per DIN EN 60715 — standard for any industrial panel. Dimensions: 45 mm wide, 90 mm tall, 75 mm deep. The ZX95 variant carries a special customer-specific code; mechanically it shares the same footprint as the base 3RV1011-0HA10, so it drops into an existing panel layout without rewiring. Screw-type terminals on the main circuit accept 2x (0.5...1.5 mm²) solid or stranded, or 2x (0.75...2.5 mm²). M3 screws for the main contacts. Mounting position any. Clearance spacings: 20 mm upwards, 20 mm downwards, 9 mm at the side, zero forwards or backwards. No external fuse required at 240 V or 400 V; at 500 V or 690 V, use a gL/gG 6 A backup fuse.

Frequently asked questions

Will 3RV1011-0HA10-ZX95 drop into a panel specified around 3RV1011-0HA10 without rewiring?

Yes. The ZX95 suffix is a customer-specific code; the mechanical footprint, terminal layout, and ratings are identical to the base 3RV1011-0HA10. Same 45 mm width, same DIN-rail clip, same screw-terminal pattern — it's a drop-in replacement.

What is the breaking capacity of 3RV1011-0HA10-ZX95 at 400 V?

Rated 100 kA at 400 V AC. Same rating holds at 240 V, 500 V, and 690 V.

Where can I buy 3RV1011-0HA10-ZX95 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the quantity for a firm price and lead time.

MPN
3RV1011-0HA10-ZX95