Skip to main content
Siemens 3RV1011-0JA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0JA10-ZI45 SIRIUS Motor Protection CB, CLASS

MPN3RV1011-0JA10-ZI45

Siemens SIRIUS 3RV1011-0JA10-ZI45, motor protection circuit breaker, CLASS 10, adjustable overload release 0.7...1 A, rated current 1 A, size S00, screw terminals, screw and snap-on mounting onto 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0JA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-0JA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0JA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10

Connections

3RV1011-0JA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom

Mechanical

3RV1011-0JA10-ZI45 — Mechanical
ParameterValue
Mounting positionany

Specifications

3RV1011-0JA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV1011-0JA10-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value250 W
Operating current rated value1 A
Adjustable pick-up value current of the current-dependent overload release0.7 ... 1 A

Product details

Motor protection circuit breaker for the 1 A line

The Siemens SIRIUS 3RV1011-0JA10-ZI45 is a motor protection circuit breaker in the compact S00 frame, sized for a 1 A rated operating current with an adjustable overload release spanning 0.7 to 1 A. Its CLASS 10 trip characteristic means it will trip within 10 seconds at 7.2× the set current — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal starting inrush. The breaker combines a thermal overload release (for sustained overcurrent) and a magnetic short-circuit trip for fault clearing, all in a three-pole package with screw-type terminals arranged top and bottom for straightforward line and load wiring. Mounting is via screw and snap-on onto 35 mm standard mounting rail per DIN EN 60715, in any position. The S00 frame width of 45 mm means it occupies a single DIN-rail module space, which simplifies panel layout when grouping multiple motor starters. Power dissipation runs 5.5 W total (1.8 W per pole) in the hot operating state — worth factoring into enclosure thermal calculations if the panel is densely packed.

Frequently asked questions

What is the trip class of 3RV1011-0JA10-ZI45?

CLASS 10 — the breaker trips within 10 seconds at 7.2× the set current, matching the requirements for standard motor starting duty.

What is the adjustable overload range on this breaker?

The adjustable current-dependent overload release covers 0.7 to 1 A, set via the rocker switch on the front of the device.

Where can I buy 3RV1011-0JA10-ZI45 and get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3RV1011-0JA10-ZI45