Skip to main content
Siemens 3RV1011-0JA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0JA10-ZI45 SIRIUS Motor Protection CB, CLASS

MPN3RV1011-0JA10-ZI45

Siemens SIRIUS 3RV1011-0JA10-ZI45, motor protection circuit breaker, CLASS 10, adjustable overload release 0.7...1 A, rated current 1 A, size S00, screw terminals, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0JA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0JA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0JA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-0JA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1011-0JA10-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-0JA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection
3RV1011-0JA10-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value250 W
Operating current rated value1 A
Adjustable pick-up value current of the current-dependent overload release0.7 ... 1 A

Product details

Motor protection circuit breaker for the 1 A line

The Siemens SIRIUS 3RV1011-0JA10-ZI45 is a motor protection circuit breaker in the compact S00 frame, sized for a 1 A rated operating current with an adjustable overload release spanning 0.7 to 1 A. The breaker combines a thermal overload release (for sustained overcurrent) and a magnetic short-circuit trip for fault clearing, all in a three-pole package with screw-type terminals arranged top and bottom for straightforward line and load wiring.

Frequently asked questions

What is the trip class of 3RV1011-0JA10-ZI45?

CLASS 10 — the breaker trips within 10 seconds at 7.2× the set current, matching the requirements for standard motor starting duty.

What is the adjustable overload range on this breaker?

The adjustable current-dependent overload release covers 0.7 to 1 A, set via the rocker switch on the front of the device.

Where can I buy 3RV1011-0JA10-ZI45 and get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3RV1011-0JA10-ZI45