Skip to main content
Siemens 3RV1011-0JA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0JA10-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1011-0JA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0JA10-ZW95, 45 mm wide, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, for motor protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0JA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0JA10-ZW95 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0JA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0JA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0JA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0JA10-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0JA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0JA10-ZW95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Trip Class and Protection Features

Rated Trip Class 10, so it trips within 10 seconds at 7.2× the thermal setting — standard for protecting standard induction motors during startup. No ground fault detection on this variant, so if your application requires that, you'd need a separate ground-fault relay or a different SIRIUS model.

The 45 mm width and 75 mm depth fit standard panel layouts — it occupies one 45 mm slot on the rail, leaving room for auxiliary contact blocks or a downstream contactor in the same footprint. Clearance requirements: 20 mm above and below, 9 mm to the side, zero forwards or backwards — tight enough for dense panels if you respect the ventilation gaps.

Frequently asked questions

What compliance documentation does Siemens provide for this part?

Standard Siemens SIRIUS documentation includes CE, UL, CSA, and CCC certifications. RoHS and REACH declarations are available on request. The part carries the SIRIUS brand and is manufactured under Siemens quality systems.

MPN