Siemens 3RV1011-0JA20-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0JA20-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1011-0JA20-ZW97

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0JA20-ZW97, 1 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V, 3-pole, spring-loaded terminals, screw and snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0JA20-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-0JA20-ZW97 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0JA20-ZW97 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-0JA20-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-0JA20-ZW97 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-0JA20-ZW97 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-0JA20-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-0JA20-ZW97 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Trip Class and Motor Protection

The 3RV1011-0JA20-ZW97: Rated CLASS 10, this breaker will trip within 10 seconds at 7.2× the thermal setting. That matches the standard protection requirement for standard squirrel-cage induction motors during a locked-rotor condition.

The 100 kA breaking capacity holds across the full voltage range: 240 V, 400 V, 500 V, and 690 V AC. That is a flat high-fault curve, not a derated one at higher voltages.

Zero clearance required at the sides and rear — the breaker can be butted directly against adjacent devices and the panel backplate. Front face carries an IP20 rating, so finger-safe when installed in an enclosure. Any mounting position is permitted.

Main circuit terminals are spring-loaded, accepting solid conductors 2x (0.25... 2.5 mm²) or finely stranded with ferrule 2x (0.25... 1.5 mm²). AWG equivalents are 2x (24... 14). No screw torque to verify — spring-clamp termination is vibration-resistant and consistent across temperature cycles.

Shock rated at 25g for 11 ms. Mechanical endurance is 100 000 cycles on the main contacts.

Frequently asked questions

Who supplies 3RV1011-0JA20-ZW97 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is 3RV1011-0JA20-ZW97's listed depth?

The listed depth is 81 mm.

What conductor sizes does the spring-loaded terminal accept?

Solid conductors: 2x (0.25... 2.5 mm²). Finely stranded with ferrule: 2x (0.25... 1.5 mm²). AWG equivalents: 2x (24... 14).

Will 3RV1011-0JA20-ZW97 drop into a panel specified around 3RV1011-0GA10 without rewiring?

Both parts share the same SIRIUS frame size, 45 mm width, and 35 mm DIN rail mounting with zero side clearance. The terminal type differs — this unit uses spring-loaded terminals versus screw-type on the 0GA10 variant — so verify the wiring method matches your panel's existing terminations.

MPN