Skip to main content
Siemens 3RV1011-0KA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0KA10-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1011-0KA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-0KA10-ZW95, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm width, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0KA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-0KA10-ZW95 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0KA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0KA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-0KA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0KA10-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-0KA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-0KA10-ZW95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker — SIRIUS 3RV1011-0KA10-ZW95

The Siemens SIRIUS 3RV1011-0KA10-ZW95 is a motor protection circuit breaker designed for motor protection, with a Class 10 trip curve that matches standard induction motor start profiles — it holds through the inrush without nuisance tripping, then clears on sustained overload within 10 seconds at 7.2× Ie. Any mounting position is allowed, simplifying layout in tight panels.

Protection features and wiring

Built-in phase failure detection protects motors against single-phasing — a common failure mode in three-phase lines that can burn out windings if undetected. No ground fault detection, so if that's required, add an external GF relay. Main circuit terminals accept screw-type connections, rated for 2× (0.5…1.5 mm²) solid or stranded, or 2× (0.75…2.5 mm²). Torque spec for M3 screws — standard for this class. Maximum switching frequency in AC-3 duty is 15 operations per hour — fine for pump and conveyor cycling, but not for high-repetition applications like stamping presses.

Frequently asked questions

Where can I buy 3RV1011-0KA10-ZW95 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 3RV1011-0KA10-ZW95 drop into a panel that was specified around 3RV1011-0GA10 without rewiring?

Both are SIRIUS motor protection breakers with the same 45 mm width and DIN rail mount, so they share the same panel footprint and rail slot. Terminal types and wiring capacities should be verified against the specific GA10 variant, but the mechanical fit is identical.

What compliance documentation does this brand provide for 3RV1011-0KA10-ZW95?

As a Siemens SIRIUS product, this breaker is typically covered by CE, UL, CSA, and RoHS declarations. Specific certificates should be requested at order time for your jurisdiction.

MPN
3RV1011-0KA10-ZW95