Siemens SIRIUS 3RV1011-0KA10-ZW98 motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0KA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-0KA10-ZW98 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0KA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-0KA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-0KA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-0KA10-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-0KA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-0KA10-ZW98 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for dusty environments

The Siemens SIRIUS 3RV1011-0KA10-ZW98 is a motor protection circuit breaker designed for the grit and heat of industrial floors — kiln rooms, crusher panels, mill MCCs. Rated Trip Class 10, it disconnects a stalled motor fast enough to keep windings intact, which matters when a conveyor jams and the line can't wait for a thermal overload to cool down. Phase failure detection is built in, so a dropped leg on a 400 V feeder won't cook the motor while the breaker sits there reading the remaining two phases. Breaking capacity hits 100 kA at 400 V — that's fault-current capability that handles the stiffest distribution transformers without cascading upstream.

Mounting and wiring in a tight panel

Snaps onto 35 mm DIN rail per DIN EN 60715, or screws direct to a backplate. The 45 mm width keeps the fill factor tight — you can pack a dozen of these across a 600 mm rail for a multi-motor group. Screw terminals on the main circuit accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²) — no ferrule crimping required for the smaller wire. Mounting position is any, so vertical or horizontal rail orientation works. Clearance: 20 mm above and below, 9 mm to the side, zero forward or backward. That 75 mm depth leaves room for wiring ducts behind a 200 mm deep enclosure.

Thermal environment and operating limits

Runs from -20 to +60 °C during operation — that covers a control room next to a preheater tower or a summer-afternoon MCC in a cement plant. Storage and transport range is -50 to +80 °C, so it survives a hot shipping container or a frozen warehouse. The rated operating voltage spans 20 to 690 V, which means it works on 240 V single-phase control transformers as well as 400 V three-phase motor feeds. For fuse backup: at 400 V use gL/gG 20 A; at 690 V step down to gL/gG 16 A. No fuse required at 240 V.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-0KA10-ZW98?

Submit an RFQ through the distributor. Availability and current pricing are confirmed at quote time — this part is sourced to order through independent distribution channels.

Will 3RV1011-0KA10-ZW98 drop into a panel specified around 3RV1011-0HA10 without rewiring?

It shares the same 45 mm width, same DIN rail mount, same screw terminal pattern, and same Class 10 trip characteristic, so it fits the same panel footprint and wiring. The difference is in the current adjustment range — verify the motor FLA against the 0HA10's dial before committing the BOM line.