Siemens 3RV1011-0KA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0KA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1011-0KA10-ZX95
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV1011-0KA10-ZX95, Class 10 trip, 100 kA SCCR at 400 V, 0.2 kW at 230 V, 45 x 90 x 75 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-0KA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-0KA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV1011-0KA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-0KA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-0KA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-0KA10-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-0KA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-0KA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV1011-0KA10-ZX95 is a SIRIUS motor protection circuit breaker designed to protect motors against overload and short-circuit. It has a Class 10 trip characteristic, meaning it disconnects within 10 seconds at 7.2x the thermal setting—fast enough for standard induction motor starts that don't drag. Rated for 0.2 kW at 230 V and 1 hp at 460/480 V, it covers small motor loads common on pumps and conveyors. The interrupting rating hits 100 kA at 240 V, 400 V, and 500 V, dropping to 2 kA at 690 V. That 100 kA SCCR at 400 V means it can safely clear a fault up to that level without upstream fuses needing to act—critical for panel SCCR compliance under UL 508A. At 690 V the 2 kA rating still covers most industrial line-to-line faults. Mounts on 35 mm DIN rail per DIN EN 60715 via screw and snap-on fastening; any mounting position works. The 45 mm width fits standard 45 mm slot spacing in most enclosures. Depth is 75 mm, height 90 mm.

Clearance and backup fuse requirements

Clearance distances: 20 mm upwards and downwards, 9 mm at the side, 0 mm forwards and backwards. That zero forward clearance means it can sit flush against a panel door or gland plate without extra breathing space. Backup fuse depends on line voltage: none required at 240 V, gL/gG 20 A at 400 V, gL/gG 16 A at 500 V and 690 V. If the available fault current exceeds the breaker's 2 kA at 690 V, the 16 A gL/gG fuse upstream ensures coordinated interruption.

Termination and environmental limits

Main circuit terminals are M3 screw-type, accepting 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. Operating temperature range -20 to +60 °C; storage and transport -50 to +80 °C. Maximum switching frequency 15 operations per hour in AC-3 and AC-3e duty. Phase failure detection is built in; ground fault detection is not. The voltage range is 20 to 690 V AC.

Frequently asked questions

Will 3RV1011-0KA10-ZX95 drop into a panel specified around 3RV1011-0HA10 without rewiring?

The 3RV1011-0KA10-ZX95 shares the same 45 mm width, 75 mm depth, 90 mm height, and DIN-rail mounting as the 3RV1011-0HA10. Clearance requirements are identical (20 mm up/down, 9 mm sides, 0 mm front/back). The terminal type and wire range are the same M3 screw-type. It should be a mechanical and electrical drop-in replacement, but verify the trip setting and SCCR match your application.

MPN
3RV1011-0KA10-ZX95