Siemens 3RV1011-0KA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-0KA15-0BA0 SIRIUS Motor Protective Circuit B

MPN3RV1011-0KA15-0BA0
Active

Siemens SIRIUS 3RV1011-0KA15-0BA0, motor-protective circuit breaker, 1.25 A continuous rated current, Class 10, 100 kA breaking capacity at 400 V AC, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-0KA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-0KA15-0BA0 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV1011-0KA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-0KA15-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1011-0KA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-0KA15-0BA0 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV1011-0KA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1011-0KA15-0BA0 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It carries a continuous rated current of 1.25 A and a Trip Class 10, meaning it trips within 10 seconds at 7.2× the set current — standard protection for standard-start induction motors driving pumps, fans, or conveyors. The overload release is thermal (bimetal), the short-circuit trip is magnetic.

Breaking capacity and mounting

Rated breaking capacity is 100 kA at 240 V, 400 V, and 500 V AC, dropping to 2 kA at 690 V AC. IP20 on the front; no washdown rating, so keep it inside the enclosure.

Frequently asked questions

What is the breaking capacity of 3RV1011-0KA15-0BA0 at 400 V?

100 kA at 400 V AC. The same 100 kA rating holds at 240 V and 500 V; at 690 V it drops to 2 kA.

Does 3RV1011-0KA15-0BA0 detect phase failure?

Yes, phase failure detection is built into the overload release. A lost phase on the supply side will cause the breaker to trip, protecting the motor from single-phasing.

Where can I buy 3RV1011-0KA15-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

MPN
3RV1011-0KA15-0BA0