Siemens 3RV1011-1AA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1AA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1011-1AA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1AA10-ZW97, Trip Class 10, 100 kA at 400 V, screw-type terminals, 45 mm wide, for 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV1011-1AA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1AA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1AA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1AA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1AA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1AA10-ZW97 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-1AA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1AA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Interrupting capacity hits 100 kA at 400 V and 500 V, and 2 kA at 690 V — so it can clear a bolted fault on a high-capacity distribution transformer without needing a current-limiting fuse upstream in most 400 V panels.

Screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) solid/stranded or 2×(0.75…2.5 mm²) — M3 screws, so a #1 Pozidriv or 5.5 mm nut driver is the tool. No ground-fault detection; if you need that, step up to the 3RV1011‑…‑ZD10 variant. Clearance: 20 mm above and below, 9 mm to the side, zero forward or backward — tight enough for a crowded DIN-rail row.

Frequently asked questions

What is the 3RV1011-1AA10-ZW97 used for?

It is a motor protection circuit breaker — overload and short-circuit protection for three-phase induction motors, with phase failure detection. Trip Class 10 matches standard motor start profiles.

Where can I buy the 3RV1011-1AA10-ZW97?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of this motor protection breaker?

Trip Class 10, interrupting capacity 100 kA at 400 V and 500 V, 2 kA at 690 V. Voltage range 20…690 V. Width 45 mm, depth 75 mm, height 90 mm. Screw terminals, DIN rail mount.

MPN
3RV1011-1AA10-ZW97