Skip to main content
Siemens 3RV1011-1AA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1AA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1011-1AA10-ZW98

Siemens SIRIUS motor-protection circuit breaker, 3RV1011-1AA10-ZW98, Class 10 trip, 100 kA breaking capacity at 400 V, screw and snap-on 35 mm DIN rail, 45 x 75 x 90 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1AA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1AA10-ZW98 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1AA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1AA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1AA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1AA10-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-1AA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1AA10-ZW98 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV1011-1AA10-ZW98 is a motor-protection circuit breaker with a Class 10 trip characteristic, meaning it disconnects within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a stall or locked-rotor event without nuisance tripping on normal start-up. The 100 kA breaking capacity at 400 V means it safely interrupts fault currents up to that level without cascading upstream; at 690 V the rating drops to 2 kA, so verify the available fault current at the installation point if running on a 690 V line. No ground-fault detection on this variant.

Clearance: 20 mm upwards, 20 mm downwards, 9 mm at the side, zero forwards or backwards. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). Torque spec for the M3 main-contact screws is standard — use a 5.5 mm nut driver. Backup fuse requirements: at 400 V and above, fit a gL/gG 20 A fuse upstream; at 240 V none is required.

Frequently asked questions

What is the closest functional second-source to 3RV1011-1AA10-ZW98?

The 3RV1011-0HA10 is a close sibling in the same SIRIUS family, sharing the same 45 mm width, DIN-rail mounting, and Class 10 trip. The key difference is the thermal setting range — verify the 0HA10's adjustment range against your motor FLA before substituting. The 3RV1011-1AA10-ZW98 drops into the same panel footprint without rewiring if the terminal ratings match.

MPN