Skip to main content
Siemens 3RV1011-1AA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1AA15 SIRIUS Circuit Breaker, Class 10, 100

MPN3RV1011-1AA15
Active

Siemens SIRIUS circuit breaker, 3RV1011-1AA15, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, screw and snap-on 35 mm DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV1011-1AA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1AA15 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1AA15 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1AA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1AA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1AA15 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-1AA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1AA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Siemens 3RV1011-1AA15 is a SIRIUS-branded circuit breaker for motor protection, rated for 20... 690 V and carrying a Class 10 trip characteristic. Breaking capacity sits at 100 kA at 400 V and 500 V, dropping to 2 kA at 690 V — the high 400 V figure means it handles bolted faults on a strong industrial grid without cascading upstream.

Auxiliary contact ratings and wiring

The integrated auxiliary contact switches 1 A at 24 V, 2 A at 110–125 V, and 0.5 A at 230 V — enough for PLC input or contactor coil feedback in a 24 VDC control loop. Terminals accept 2× (0.5... 1.5 mm²) or 2× (0.75... 2.5 mm²) solid or stranded wire, secured with M3 screws. The 9 mm side clearance and 20 mm upward/downward clearance simplify wiring in a dense row.

Frequently asked questions

Is the 3RV1011-1AA15 obsolete or still active, and are there any PCN or last-time-buy notices?

Buyers and storerooms must decide whether to stock or qualify alternates before allocation hits.

Where can I buy a traceable 3RV1011-1AA15 with current stock, MOQ, and lead time?

Sourcing needs authorized-channel proof, pricing tiers, and ship dates to place a PO confidently.

What is the authorized cross reference or equivalent MPCB for the 3RV1011-1AA15?

Maintenance and MRO require a drop-in alternate to avoid downtime when stock is constrained.

What are the breaking capacity, trip class, and current setting range of the 3RV1011-1AA15?

Designers and power engineers need kAIC at 400 V and Class 10 trip data for coordination studies.

Which auxiliary contact modules, link bars, and accessories fit the 3RV1011-1AA15 frame?

Panel builders and PLC engineers must avoid I/O mapping errors from mismatched aux blocks.

What is the correct wiring, torque, wire gauge, and DIN-rail installation procedure for the 3RV1011-1AA15?

Wiremen need terminal specs and clearances to build compliant panels without rework.

MPN