Siemens 3RV1011-1AA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1AA15-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV1011-1AA15-0BA0
Active

Siemens SIRIUS 3RV1011-1AA15-0BA0, motor protection circuit breaker, 1.6 A rated continuous current, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV1011-1AA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1AA15-0BA0 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1AA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1AA15-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1011-1AA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14)
3RV1011-1AA15-0BA0 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1011-1AA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1011-1AA15-0BA0 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker for 0.55 kW Loads

The Siemens SIRIUS 3RV1011-1AA15-0BA0 is a motor protection circuit breaker rated for 1.6 A continuous current, sized for a 0.55 kW motor at 400 V AC.

DIN Rail Mounting and Panel Fit

The 45 mm wide, 90 mm tall, 81 mm deep footprint fits a standard 4-module width on the rail, leaving room for a contactor and overload relay in a motor starter lineup. Any mounting position is permitted, so vertical or horizontal rail orientation works. Screw-type terminals on both main and auxiliary circuits accept solid conductors: 2× (0.5…1.5 mm²) and 2× (0.75…2.5 mm²), or stranded equivalents. AWG equivalents for main contacts are 2× (18…14). Zero clearance required at the sides or rear for heat dissipation.

Breaking capacity holds at 100 kA across 240 V, 400 V, and 500 V AC, then drops to 2 kA at 690 V AC.

Shock rated at 25g for 11 ms. RoHS compliance is documented with a substance prohibition date of 01/01/2013.

Frequently asked questions

Where can I buy 3RV1011-1AA15-0BA0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the depth of 3RV1011-1AA15-0BA0?

The depth is 81 mm, with a width of 45 mm and height of 90 mm.

What conductor sizes does the 3RV1011-1AA15-0BA0 accept?

Solid conductors: 2× (0.5…1.5 mm²) and 2× (0.75…2.5 mm²). Stranded: same ranges. AWG for main contacts: 2× (18…14).

Does 3RV1011-1AA15-0BA0 have phase failure protection?

Yes, phase failure detection is built into the overload release. Ground fault detection is not included.