Skip to main content
Siemens 3RV1011-1AA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1AA20 SIRIUS Motor Protection Circuit Breake

MPN3RV1011-1AA20

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1AA20, 1.6 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, 3-pole, IP20 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1AA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1AA20 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1AA20 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1AA20 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1011-1AA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (24 ... 14)
3RV1011-1AA20 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1011-1AA20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1011-1AA20 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-1AA20 is a SIRIUS motor protection circuit breaker rated for 1.6 A continuous current, designed to protect three-phase motors up to 0.55 kW at 400 V AC. No ground-fault detection here, so plan for a separate ground-fault relay if that's required. The 3-pole design handles the three-phase main circuit; spring-loaded terminals on both main and auxiliary circuits accept 0.25–2.5 mm² solid or 0.25–1.5 mm² finely stranded with ferrules. Dimensions are 45 mm wide, 90 mm high, 81 mm deep — zero clearance needed at the sides or rear.

At 690 V AC it drops to 2 kA — that's the limit for 690 V systems; above that voltage, coordination with upstream protection is essential. For typical 400 V distribution panels, the 100 kA rating gives plenty of headroom for high-fault installations.

Power Loss and Duty Cycle

Total power loss in hot operating state is 7.25 W, with 2.4 W per pole. That's modest — no special ventilation needed in a standard enclosure. Maximum operating frequency at AC-3 duty is 15 operations per hour, which suits typical motor start cycles for pumps, fans, and conveyors. For higher cycling applications like rapid reversing drives, consider a contactor with a higher rated frequency.

Frequently asked questions

Where can I buy 3RV1011-1AA20 and how do I get a price?

We source the 3RV1011-1AA20 to order against an RFQ. Submit a request with your quantity and target delivery date; we'll confirm availability and current pricing at quote time.

What is 3RV1011-1AA20's listed depth?

The depth is 81 mm. Combined with a width of 45 mm and height of 90 mm, it fits a standard DIN-rail footprint with zero clearance at sides or rear.

What compliance documentation does Siemens provide for 3RV1011-1AA20?

The part is RoHS compliant with a substance prohibition date of 01.01.2013. Standard Siemens documentation includes the declaration of conformity and CE marking; request specific certificates (UL, IEC) at RFQ time.

Will 3RV1011-1AA20 drop into a panel specified around 3RV1011-1AA15?

Both are SIRIUS motor protection breakers with the same 45 mm width and DIN-rail mounting. The key difference is the continuous current rating: 1.6 A on the 1AA20 versus 1.0 A on the 1AA15. If the motor load is ≤1.0 A, the 1AA15 is the correct fit; for loads up to 1.6 A, the 1AA20 works. Terminal types and wiring ranges are identical (spring-loaded, 0.25–2.5 mm²), so no rewiring needed.

MPN