3RV1011-1BA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1BA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1BA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1BA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1BA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1BA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1BA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1BA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-1BA10-0FJ0-ZX95 is a SIRIUS-series motor protection circuit breaker — a compact, DIN-rail-mounted device that combines a thermal-magnetic overload relay and a short-circuit trip in one housing, sized for motor circuits up to 2 A continuous current.

The 2 A continuous current rating sets the maximum full-load current the breaker can carry continuously without tripping. For a 400 V three-phase motor, this corresponds to a 0.75 kW motor rating — so it's sized for small drives like fans, pumps, or conveyor sections under that power. That's fast enough to protect a standard motor winding during a locked-rotor event while allowing normal starting inrush for most general-purpose motors. Breaking capacity: 100 kA at 400 V AC, 100 kA at 240 V AC, 10 kA at 500 V AC, and 2 kA at 690 V AC. Mechanical endurance is rated at 100,000 operations for the main contacts. Maximum switching rate is 15 operations per hour at AC-3.

Mounting and wiring — what fits in the panel

Width 45 mm, height 90 mm, depth 81 mm — this is a compact 45 mm-wide frame that clips onto 35 mm DIN rail per EN 50022. No rear clearance needed (0 mm backwards), and 0 mm side clearance required, so you can pack breakers side-by-side without derating for spacing. Terminals accept solid or stranded conductors: 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) per clamp, with AWG equivalents 2× (18…14).

Front face is rated IP20 — finger-safe when installed in an enclosure, but not protected against moisture ingress. Shock resistance rated at 25g for 11 ms, surge voltage resistance 6 kV. This matters for thermal calculations inside a sealed panel — at 2 A it's modest, but in a densely packed row the heat adds up.

Frequently asked questions

Does this breaker include phase failure protection?

Yes, phase failure detection is built in — it will trip if one phase is lost, preventing single-phasing damage to the motor.

Will this drop into a panel specified around the 3RV1011-1HA10 without rewiring?

Both are 45 mm-wide SIRIUS motor protection breakers with the same DIN-rail footprint and screw-type terminals, so mechanical fit is identical. The key difference is the current rating — verify your motor's FLA against the 2 A rating of this variant before substituting.