Siemens 3RV1011-1BA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1BA10-ZI45 SIRIUS Motor Circuit Breaker, 1.4

MPN3RV1011-1BA10-ZI45

Siemens SIRIUS 3RV1011-1BA10-ZI45, motor protection circuit breaker size S00, CLASS 10, A-release 1.4...2 A, N-release 26 A, screw terminal, standard switching capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1BA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1BA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1BA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-1BA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1011-1BA10-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-1BA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Its adjustable overload release covers a range of 1.4 to 2 A, and it carries a CLASS 10 trip class, meaning it will trip within 10 seconds at 7.2× the set current — appropriate for protecting standard induction motors during startup without nuisance tripping on the inrush.

The S00 frame keeps the footprint compact for panel integration. Screw-type terminals on top and bottom accept the main circuit wiring. At 400 V the breaker is rated for 750 W motor power.

Frequently asked questions

What does the CLASS 10 trip class mean for motor protection?

CLASS 10 means the overload release will trip within 10 seconds at 7.2× the set current. This suits standard induction motors with moderate startup times — fast enough to protect the motor winding, slow enough to ride through the inrush without nuisance tripping.

What is the adjustable overload range on this breaker?

The current-dependent overload release adjusts from 1.4 to 2 A. The magnetic short-circuit trip is fixed at 26 A.

Where can I buy the 3RV1011-1BA10-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 3RV1011-1BA10-ZI45 drop into a panel specified for the 3RV1011-1HA10?

Both share the same S00 frame size, DIN rail mounting, and screw terminal arrangement. The key difference is the overload range: this unit adjusts 1.4...2 A, while the 1HA10 covers 5.5...8 A. Panel cutouts and wiring positions are identical, so a swap requires only adjusting the overload setting — no rewiring.