Skip to main content
Siemens 3RV1011-1BA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1BA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1011-1BA10-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1BA10-ZW98, Class 10, 100 kA SCCR at 400 V, 45 mm width, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1BA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1BA10-ZW98 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1BA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1BA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1BA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1BA10-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-1BA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1BA10-ZW98 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

The Siemens 3RV1011-1BA10-ZW98 is a SIRIUS motor protection circuit breaker designed for motor protection, with screw-type terminals for the main current circuit and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Trip Class 10 means it clears overloads within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors during start-up without nuisance tripping on normal acceleration.

Short-circuit and coordination ratings

Rated short-circuit breaking capacity reaches 100 kA at 240 V, 400 V, and 500 V — sufficient for high-fault-current industrial panels without requiring upstream current-limiting fuses in many configurations. At 690 V the SCCR is 2 kA. For backup fuse coordination, the evidence specifies gL/gG 35 A at 400 V and gL/gG 25 A at 500 V and 690 V — no fuse required at 240 V.

Minimum clearance: 20 mm upward, 20 mm downward, 9 mm at the side; no clearance needed forward or backward. Terminal capacity accepts 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded copper; screw-type terminals for the main circuit use M3 screws. Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C.

Frequently asked questions

Will 3RV1011-1BA10-ZW98 drop into a panel specified around 3RV1011-1AA15 without rewiring?

Both are 45 mm wide SIRIUS motor protection breakers sharing the same DIN-rail footprint and screw-terminal pattern, so mechanical fit is identical — but verify the specific trip-current setting and SCCR rating of the 1AA15 variant against your load before substitution.

What is the depth of 3RV1011-1BA10-ZW98?

The depth is 75 mm.

MPN
3RV1011-1BA10-ZW98