Skip to main content
Siemens 3RV1011-1BA10-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1BA10-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1011-1BA10-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1BA10-ZW98, Class 10, 100 kA SCCR at 400 V, 45 mm width, screw and snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1BA10-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-1BA10-ZW98 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1BA10-ZW98 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-1BA10-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-1BA10-ZW98 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-1BA10-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-1BA10-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-1BA10-ZW98 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

The Siemens 3RV1011-1BA10-ZW98 is a SIRIUS motor protection circuit breaker designed for motor protection, with screw-type terminals for the main current circuit and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Its 45 mm width and 75 mm depth fit standard panel layouts, and the mounting position is any orientation, simplifying enclosure layout. Trip Class 10 means it clears overloads within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors during start-up without nuisance tripping on normal acceleration.

Short-circuit and coordination ratings

Rated short-circuit breaking capacity reaches 100 kA at 240 V, 400 V, and 500 V — sufficient for high-fault-current industrial panels without requiring upstream current-limiting fuses in many configurations. At 690 V the SCCR is 2 kA. For backup fuse coordination, the evidence specifies gL/gG 35 A at 400 V and gL/gG 25 A at 500 V and 690 V — no fuse required at 240 V.

Integration notes for the panel builder

Mounts via screw and snap-on onto 35 mm DIN rail (DIN EN 60715). Minimum clearance: 20 mm upward, 20 mm downward, 9 mm at the side; no clearance needed forward or backward. Terminal capacity accepts 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded copper; screw-type terminals for the main circuit use M3 screws. Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C.

Frequently asked questions

Will 3RV1011-1BA10-ZW98 drop into a panel specified around 3RV1011-1AA15 without rewiring?

Both are 45 mm wide SIRIUS motor protection breakers sharing the same DIN-rail footprint and screw-terminal pattern, so mechanical fit is identical — but verify the specific trip-current setting and SCCR rating of the 1AA15 variant against your load before substitution.

What is the depth of 3RV1011-1BA10-ZW98?

The depth is 75 mm.

MPN
3RV1011-1BA10-ZW98