Siemens 3RV1011-1BA15-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1BA15-ZI45 SIRIUS Motor Protection Circuit B

MPN3RV1011-1BA15-ZI45

Siemens SIRIUS 3RV1011-1BA15-ZI45 motor protection circuit breaker, CLASS 10, adjustable overload release 1.4–2 A, magnetic short-circuit release 26 A, size S00, screw terminals, integrated transverse auxiliary switch 1 NO+1 NC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1BA15-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-1BA15-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1BA15-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10

Connections

3RV1011-1BA15-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom

Mechanical

3RV1011-1BA15-ZI45 — Mechanical
ParameterValue
Mounting positionany

Specifications

3RV1011-1BA15-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV1011-1BA15-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value750 W
Operating current rated value2 A
Adjustable pick-up value current of the current-dependent overload release1.4 ... 2 A

Product details

Motor protection circuit breaker, size S00, CLASS 10, 2 A

The Siemens SIRIUS 3RV1011-1BA15-ZI45 is a motor protection circuit breaker sized S00, designed for protecting three-phase induction motors up to 2 A rated operating current. Its CLASS 10 trip characteristic means the overload release will trip within 10 seconds at 7.2× the current setting — fast enough to protect standard squirrel-cage motors against locked-rotor heating without nuisance tripping during normal starting. The adjustable overload release covers 1.4 to 2 A, letting you fine-tune the protection to the motor's full-load current without swapping the breaker. The magnetic short-circuit release is fixed at 26 A, providing instantaneous trip for fault currents above that threshold. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, in any orientation. The size S00 footprint — 45 mm wide — fits standard motor starter combinations alongside SIRIUS contactors of the same frame size. Screw-type terminals on top and bottom accept solid or stranded copper up to 2.5 mm².

Integrated auxiliary switch and panel integration

This variant includes a factory-fitted transverse auxiliary switch with one normally open and one normally closed contact. The auxiliary contacts share the same screw-terminal block and are rated for control-circuit switching — useful for signaling the breaker state to a PLC or for electrical interlocking in a starter combination. Power loss at rated current in hot operating state is 7.25 W total, 2.4 W per pole. In a densely populated panel, that heat must be considered for enclosure ventilation and derating of adjacent devices.

Frequently asked questions

What mounting does 3RV1011-1BA15-ZI45 require?

Screw and snap-on mounting onto 35 mm standard mounting rail per DIN EN 60715, in any mounting position.

What is the adjustable overload range of this circuit breaker?

1.4 to 2 A, with a fixed magnetic short-circuit release of 26 A.

MPN
3RV1011-1BA15-ZI45