Siemens 3RV1011-1CA10-0FJ0-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA10-0FJ0-ZX95 SIRIUS Motor Protective Circ

MPN3RV1011-1CA10-0FJ0-ZX95

Siemens SIRIUS, motor-protective circuit breaker, 3RV1011-1CA10-0FJ0-ZX95, 2.5 A continuous, CLASS 10 trip, 100 kA breaking at 400 V AC, phase-failure detection, screw and snap-on DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1CA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1CA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1CA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-1CA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-1CA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-1CA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-1CA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-1CA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS Motor-Protective Circuit Breaker for 2.5 A Lines

The Siemens SIRIUS 3RV1011-1CA10-0FJ0-ZX95 is a motor-protective circuit breaker rated at 2.5 A continuous current, with a CLASS 10 trip curve and integrated phase-failure detection. It breaks up to 100 kA at 400 V AC, dropping to 10 kA at 500 V and 2 kA at 690 V — the 100 kA figure governs most 400 V industrial distribution panels; the 690 V rating matters only if the breaker sits on the secondary of a step-up transformer or in a 690 V motor circuit. Mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 50022, any position. The 45 mm width and 81 mm depth fit a standard 45 mm-wide DIN-rail slot — no extra side clearance needed (0 mm at the side, 0 mm backwards). Front face carries IP20 protection; the enclosure is designed for panel interiors where tools and fingers are the main contact risk. Screw-type terminals for the main circuit accept 2x (0.5…1.5 mm²) solid or 2x (0.75…2.5 mm²) stranded — typical for a 2.5 A motor branch.

Peer Fit Note

The 3RV1011-1HA10 is a close functional peer within the same SIRIUS family. Both share the 45 mm width, CLASS 10 trip, phase-failure detection, and the same DIN-rail mounting footprint. The difference is in the continuous current rating and the breaking capacity at higher voltages — the -1HA10 is a higher-current variant. If your panel was specified around the -1HA10, the -1CA10-0FJ0-ZX95 will physically drop into the same rail slot and terminal pattern, but the continuous current rating must match your motor full-load amps; swapping between them without verifying the load current risks nuisance tripping or inadequate protection.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-1CA10-0FJ0-ZX95?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability.

What is the closest functional second-source to 3RV1011-1CA10-0FJ0-ZX95?

The 3RV1011-1HA10 is a close functional peer in the same SIRIUS family, sharing the same 45 mm width, CLASS 10 trip, phase-failure detection, and DIN-rail mount. However, the continuous current rating differs — verify motor FLA before substituting.

What is the depth of 3RV1011-1CA10-0FJ0-ZX95?

The depth is 81 mm.

What conductor sizes does the 3RV1011-1CA10-0FJ0-ZX95 accept?

Solid conductors: 2x (0.5…1.5 mm²) or 2x (0.75…2.5 mm²); stranded conductors: same ranges. AWG equivalents: 2x (18…14).

Will 3RV1011-1CA10-0FJ0-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Yes, physically — same 45 mm width, same DIN-rail mount, same terminal pattern. But the continuous current rating differs; verify that the 2.5 A rating matches your motor load before installation.