Siemens 3RV1011-1CA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA15-0BA0 SIRIUS Motor Circuit Breaker, 2.5

MPN3RV1011-1CA15-0BA0
Active

Siemens SIRIUS motor-protective circuit breaker, 3RV1011-1CA15-0BA0, 2.5 A continuous, Class 10 thermal-magnetic trip, 100 kA SCCR at 400 V AC, screw terminals, IP20 front, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1CA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1CA15-0BA0 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1CA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1CA15-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1011-1CA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1CA15-0BA0 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV1011-1CA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m
3RV1011-1CA15-0BA0 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1011-1CA15-0BA0 — motor-protective circuit breaker, 2.5 A, Class 10

Rated short-circuit breaking capacity hits 100 kA at 240 V and 400 V AC, then derates to 10 kA at 500 V and 2 kA at 690 V — the 100 kA figure covers the common 400 V distribution level, so it coordinates with most panelboard bus bracing without an upstream current-limiting fuse. Phase failure detection trips the breaker if one phase drops out. No ground-fault detection on this variant.

Screw-type terminals on both main and auxiliary circuits; the main circuit accepts 2x (0.5…1.5 mm²) solid or 2x (0.75…2.5 mm²) stranded per pole. Zero clearance required at the sides and rear — you can butt adjacent devices directly. Shock rated at 25g / 11 ms. Mount in any orientation.

Auxiliary switch and control circuit

This variant includes a factory-fitted auxiliary switch, transverse design, with switching capacity rated at 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V — enough to signal a PLC input or drop out a holding contactor. Rated insulation voltage 20…690 V, covering low-voltage control circuits up to 690 V line-to-line.

Frequently asked questions

When sourcing 3RV1011-1CA15-0BA0, what's the closest functional second-source — 3RV1011-1HA10?

The 3RV1011-1HA10 is a sibling in the same SIRIUS 3RV10 frame, but it differs in current rating and auxiliary configuration. The 3RV1011-1CA15-0BA0 carries a 2.5 A continuous rating with a factory auxiliary switch; the 1HA10 variant has a different current setting and may lack the auxiliary. Verify the specific rating and auxiliary requirement before substituting — the physical footprint (45 mm width, DIN rail mount) is shared, so it will fit the same panel location.

What is 3RV1011-1CA15-0BA0's listed depth (81 mm) on this component line?

The depth is 81 mm, with a width of 45 mm and height of 90 mm.

What is 3RV1011-1CA15-0BA0's listed solid (2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²)) on this component line?

The main circuit screw terminals accept 2x (0.5…1.5 mm²) solid or 2x (0.75…2.5 mm²) stranded per pole.

Will 3RV1011-1CA15-0BA0 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?

The 45 mm width and DIN rail mounting are shared across the 3RV10 frame, so mechanical fit is identical. However, the current rating and auxiliary switch configuration differ — the 1CA15-0BA0 is 2.5 A with a factory auxiliary; the 1HA10 may have a different rating and no auxiliary. Check the existing wiring diagram: if the 1HA10 used the auxiliary contacts, the 1CA15-0BA0 has them; if the current setting is different, the overload adjustment range may not match.