Siemens 3RV1011-1CA20-ZW95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA20-ZW95 SIRIUS Motor Protection Circuit B

MPN3RV1011-1CA20-ZW95

Siemens SIRIUS 3RV1011-1CA20-ZW95, motor protection circuit breaker, 2.5 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, IP20 front, 45 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1CA20-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1CA20-ZW95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1CA20-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-1CA20-ZW95 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1011-1CA20-ZW95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (24 ... 14)

Mechanical

3RV1011-1CA20-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1011-1CA20-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1011-1CA20-ZW95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1011-1CA20-ZW95 is a motor protection circuit breaker rated for 2.5 A continuous current, sized for a 0.75 kW motor at 400 V. Its CLASS 10 trip characteristic means it will disconnect within 10 seconds under a locked-rotor condition — fast enough to protect standard induction motors from overheating during a stall.

Breaking capacity and coordination

At 400 V AC this breaker interrupts fault currents up to 100 kA, which covers most industrial panel SCCR requirements. At 690 V the breaking capacity drops to 2 kA — still adequate for a motor branch circuit on a 690 V system, but coordination with an upstream fuse or MCCB needs to account for that lower ceiling.

Mounting and wiring

Snap-on mounting onto 35 mm DIN rail per EN 50022, 45 mm wide — takes one standard 9 mm pitch. Spring-loaded terminals on both main and auxiliary circuits accept 0.25 to 2.5 mm² solid or stranded wire, or 0.25 to 1.5 mm² finely stranded with ferrule. No screwdriver needed for termination; strip length is 8 mm for a clean connection.

Frequently asked questions

What is the closest functional second-source for 3RV1011-1CA20-ZW95?

The 3RV1011-1HA10 is a peer in the same SIRIUS family. The key difference is the continuous current rating — 3RV1011-1CA20-ZW95 is set for 2.5 A, while the 1HA10 variant covers a different trip range. Verify the motor FLA before substituting; the footprint and terminal style are the same, so it will drop into the same DIN rail slot without rewiring.

Where can I buy 3RV1011-1CA20-ZW95?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV1011-1CA20-ZW95