Siemens 3RV1011-1CA20-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA20-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1011-1CA20-ZW98

Siemens SIRIUS, motor protection circuit breaker, 3RV1011-1CA20-ZW98, 2.5 A continuous current, CLASS 10, spring-loaded terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1CA20-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1CA20-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1CA20-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1CA20-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1CA20-ZW98 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-1CA20-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1CA20-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1CA20-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this circuit breaker is

It is rated for a continuous current of 2.5 A and carries a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× rated current — the standard for standard-duty motor starts.

At 400 V — the most common industrial distribution voltage — it can safely interrupt a 100 kA prospective fault current, which covers virtually all standard panelboard installations without needing upstream current-limiting fuses.

The 45 mm width takes up a single modular slot. Spring-loaded terminals for the main circuit accept 2x (0.25... 2.5 mm²) solid or 2x (0.25... 1.5 mm²) finely stranded with ferrule. Any mounting position is permitted.

Frequently asked questions

What is the breaking capacity of 3RV1011-1CA20-ZW98 at 400 V?

100 kA at 400 V AC.

What is the trip class of this motor protection breaker?

CLASS 10 — trips within 10 seconds at 7.2× rated current.

What terminals does 3RV1011-1CA20-ZW98 use?

Spring-loaded terminals for the main current circuit, accepting 2x (0.25... 2.5 mm²) solid or 2x (0.25... 1.5 mm²) finely stranded with ferrule.

Where can I buy 3RV1011-1CA20-ZW98?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV1011-1CA20-ZW98