Siemens 3RV1011-1CA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA25 SIRIUS Motor Protection Circuit Breake

MPN3RV1011-1CA25

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1CA25, 2.5 A rated continuous current, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, screw and snap-on 35 mm DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1CA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1CA25 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1CA25 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-1CA25 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1011-1CA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (24 ... 14)

Mechanical

3RV1011-1CA25 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1011-1CA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1011-1CA25 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

SIRIUS 3RV1011-1CA25 — motor protection circuit breaker, 2.5 A, Class 10

The Siemens 3RV1011-1CA25 is a SIRIUS motor protection circuit breaker rated for 2.5 A continuous current with a Class 10 trip characteristic, designed to protect three-phase induction motors up to 0.75 kW at 400 V. It carries a 100 kA breaking capacity at 400 V AC, meaning it can safely interrupt a fault current up to that level without upstream fuses needing to clear first — a genuine high-fault rating for a compact 45 mm wide device. Phase failure detection is built in, so it will trip on loss of a phase, preventing single-phasing damage to the motor. The spring-loaded terminals accept 2x (0.25...2.5 mm²) solid or stranded wire, or 2x (24...14) AWG, with no screw-torque requirement — a time-saver on the panel build.

Mounting and panel fit

Mounts via screw or snap-on onto 35 mm standard mounting rail per DIN EN 50022. Dimensions are 45 mm wide, 90 mm high, 81 mm deep — a standard SIRIUS breaker footprint that drops into existing 3RV1 panel layouts without re-drilling. No clearance needed at the sides or rear, so you can pack breakers tight on the rail. Any mounting position, and the IP20 front protection keeps fingers clear of live terminals inside the enclosure.

Breaking capacity and selectivity

The 100 kA breaking capacity at 240 V and 400 V AC drops to 10 kA at 500 V and 2 kA at 690 V. At 400 V — the most common industrial motor voltage — the 100 kA rating means this breaker can be used at the main distribution point without a backup fuse for most installations, provided the prospective short-circuit current stays under that figure. The 690 V rating of 2 kA is lower but still adequate for most 690 V motor circuits where the transformer impedance limits fault current. The surge voltage resistance of 6 000 V aligns with IEC 60947-2 overvoltage category III.

Environmental and compliance

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Shock resistance is 25 g for 11 ms. The substance prohibition date of 01.01.2013 aligns with RoHS and REACH compliance deadlines — the part is manufactured to meet those substance restrictions. Power dissipation in hot operating state is 7.25 W, relevant for enclosure thermal calculations when multiple breakers are ganged.

Frequently asked questions

Will 3RV1011-1CA25 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Yes, the 3RV1011-1CA25 shares the same 45 mm DIN-rail footprint, Class 10 trip characteristic, and spring-loaded terminal system as the 3RV1011-1HA10. The main power and control wiring positions are identical. The only difference is the auxiliary switch design (transverse on this unit), so verify the auxiliary contact wiring matches your control scheme before swapping.

What is 3RV1011-1CA25's listed depth?

81 mm. Combined with the 45 mm width and 90 mm height, this is the standard SIRIUS 3RV1 breaker depth that fits existing panel layouts.

MPN
3RV1011-1CA25