Siemens 3RV1011-1DA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1DA10-ZI45 SIRIUS Motor Protection CB, CLASS

MPN3RV1011-1DA10-ZI45

Siemens SIRIUS 3RV1011-1DA10-ZI45 motor protection circuit breaker, Size S00, CLASS 10, adjustable overload release 2.2-3.2 A, magnetic short-circuit release 42 A, screw terminals, snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1DA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-1DA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1DA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10

Connections

3RV1011-1DA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom

Mechanical

3RV1011-1DA10-ZI45 — Mechanical
ParameterValue
Mounting positionany

Specifications

3RV1011-1DA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV1011-1DA10-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value1 100 W
Operating current rated value3.2 A
Adjustable pick-up value current of the current-dependent overload release2.2 ... 3.2 A

Product details

Motor protection breaker, S00 frame, CLASS 10

The Siemens SIRIUS 3RV1011-1DA10-ZI45 is a motor protection circuit breaker in the compact S00 frame, designed for protecting three-phase induction motors up to the rated operating current of 3.2 A. It snaps onto 35 mm DIN rail (DIN EN 60715) and accepts screw-type terminals top and bottom for main current connections. The CLASS 10 trip class means the overload release trips within 10 seconds at 7.2× the current setting — fast enough to protect standard squirrel-cage motors against locked-rotor heating, without nuisance tripping on normal starts. The adjustable overload release covers 2.2 to 3.2 A, set via a dial on the front; the fixed magnetic short-circuit release trips at 42 A, clearing faults up to 100 kA at 400 V AC.

Mounting and panel fit

Mounts in any position on 35 mm DIN rail — the S00 footprint is 45 mm wide, 75 mm deep (excluding terminals), with 20 mm clearance above and below for wire bending. Screw terminals accept 2×(0.75 to 2.5 mm²) solid or stranded, or 2×4 mm². Torque to 0.8–1.2 N·m.

Frequently asked questions

What is the trip class of 3RV1011-1DA10-ZI45?

CLASS 10 — the overload release trips within 10 seconds at 7.2× the current setting, matching standard motor starting curves.

What is the closest functional peer — 3RV6011-0CA10?

The 3RV6011-0CA10 is the same S00 frame, CLASS 10, but rated at 0.25 A (adjustable 0.18–0.25 A) — a much smaller motor range. It will not drop into the same BOM line; the 3RV1011-1DA10-ZI45 covers 2.2–3.2 A. No rewiring difference — both use the same DIN rail footprint and screw terminals.

Where can I buy 3RV1011-1DA10-ZI45 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest position.