Siemens SIRIUS, motor-protective circuit breaker, 3RV1011-1EA10-0FJ0-ZX95, 4 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1EA10-0FJ0-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1EA10-0FJ0-ZX95 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1EA10-0FJ0-ZX95 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-1EA10-0FJ0-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-1EA10-0FJ0-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-1EA10-0FJ0-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-1EA10-0FJ0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-1EA10-0FJ0-ZX95 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1011-1EA10-0FJ0-ZX95 is a motor-protective circuit breaker rated for 4 A continuous current. It carries a CLASS 10 trip characteristic. Breaking capacity hits 100 kA at 400 V AC (also 100 kA at 240 V AC), so it can interrupt bolted faults on high-capacity distribution without cascading upstream. At 500 V AC the rating drops to 3 kA; at 690 V AC to 2 kA — a reminder that for 480 V or 600 V class systems the SCCR headroom narrows and coordination studies should confirm the let-through. Phase failure detection is built in — a critical feature for motor protection: if one phase drops on a delta-connected load, the breaker opens before single-phasing cooks the winding. No ground-fault detection on this variant, so any ground-leakage trip would need an external module or relay.

Mounting and integration

Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022. The 45 mm width and 90 mm height keep it to a single 45 mm module — fits a standard panel slot without crowding adjacent breakers or contactors. Depth is 81 mm, so verify enclosure depth if back-panel wiring or busbars are tight. IP20 on the front — touch-safe for panel installation but not for washdown or outdoor exposure. Mounting position is any, which helps when panels are oriented horizontally or on a swing frame. Terminals accept solid or stranded conductors: 2×(0.5…1.5 mm²) and 2×(0.75…2.5 mm²) per clamp, or 2× AWG 18…14 for the main contacts. Screw-type terminals — no spring-cage variant here; expect a screwdriver for termination.

Frequently asked questions

Does this breaker include phase failure protection?

Yes, phase failure detection is built in. It opens the circuit if one phase is lost, preventing single-phasing damage to motor windings. Ground fault detection is not included on this variant.

Will 3RV1011-1EA10-0FJ0-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Both are 45 mm wide SIRIUS 3RV1 motor-protective breakers on the same DIN-rail footprint, so the mechanical fit is the same. However, the 1HA10 variant has a different current rating and trip setting. Verify the overload setting matches the motor FLA before swapping — the housing and terminal layout are identical, but the protection curve may differ.