Skip to main content
Siemens 3RV1011-1EA15-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1EA15-ZI45 SIRIUS Motor Protector, 4 A, CLAS

MPN3RV1011-1EA15-ZI45

Siemens SIRIUS motor-protective circuit breaker, size S00, CLASS 10, adjustable overload release 2.8…4 A, screw terminals, DIN-rail mount, with transverse auxiliary switch 1 NO+1 NC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1EA15-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1EA15-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1EA15-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-1EA15-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1011-1EA15-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-1EA15-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection
3RV1011-1EA15-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value1 500 W
Operating current rated value4 A
Adjustable pick-up value current of the current-dependent overload release2.8 ... 4 A

Product details

The overload release adjusts from 2.8 to 4 A via a dial, and it comes with a built-in transverse auxiliary switch (1 NO + 1 NC) for status feedback.

The adjustable overload range of 2.8…4 A covers small motors in the 0.75–1.5 kW ballpark at 400 V (the part is rated 1500 W at 400 V). The magnetic short-circuit trip responds at 52 A (N release), clearing faults before the contactor welds. Size S00 keeps the footprint compact — 45 mm wide — so it fits neatly on a DIN rail alongside a S00 contactor in a motor starter assembly. The screw-type terminals accept 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid/stranded wire, and the mounting position is unrestricted (any orientation).

Frequently asked questions

What is the trip class of this circuit breaker?

The trip class is CLASS 10, meaning it trips within 10 seconds at 7.2× the set overload current — suitable for standard motor starting profiles.

What mounting does this part require?

It mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 60715, and can be installed in any position.

Will 3RV1011-1EA15-ZI45 drop into a panel specified around 3RV1011-1HA10?

Both are size S00, same DIN-rail footprint and screw-terminal arrangement, so the mechanical fit is identical. The key difference is the current range: this one adjusts 2.8–4 A, while the 1HA10 covers 5.5–8 A. If the motor load falls within 2.8–4 A, it is a direct swap without rewiring.

Where can I buy 3RV1011-1EA15-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

MPN
3RV1011-1EA15-ZI45