Siemens 3RV1011-1EA20-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1EA20-ZW98 SIRIUS Motor Protection Circuit B

MPN3RV1011-1EA20-ZW98

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1EA20-ZW98, 4 A continuous, 100 kA breaking at 400 V AC, Class 10 trip, spring-loaded terminals, 3-pole, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1EA20-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1EA20-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1EA20-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-1EA20-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-1EA20-ZW98 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)

Mechanical

3RV1011-1EA20-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-1EA20-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-1EA20-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What this breaker does on the line

The Siemens SIRIUS 3RV1011-1EA20-ZW98 is a 3-pole motor protection circuit breaker rated for 4 A continuous current and a 1.5 kW motor at 400 V AC. Its Class 10 trip characteristic means it clears overloads fast enough to protect standard induction motors during start-up — no nuisance tripping on inrush, but a locked-rotor condition gets caught inside 10 seconds at 7.2× Ie. That 100 kA breaking capacity at 400 V AC gives you full selectivity on most distribution panels without needing an upstream fuse for SCCR compliance. Phase failure detection is built in — if one leg drops, the breaker trips, which matters on delta-connected motors that can single-phase and burn up without a visible overload. No ground-fault detection here, so plan for a separate GF relay if the circuit requires it.

Mounting and wiring — what fits

Snaps onto a 35 mm DIN rail per EN 50022. The 45 mm width and 90 mm height are standard for this SIRIUS frame size; depth is 81 mm — check that against your enclosure depth, especially if a door-mounted operator or auxiliary block goes on the front. Zero clearance needed at the back or sides, so you can pack breakers tight on the rail. Any mounting position works. Main circuit terminals are spring-loaded, accepting solid or stranded copper: 2x (0.25…2.5 mm²) solid, or 2x (0.25…1.5 mm²) finely stranded with ferrule. AWG equivalent is 24–14. No screw torque to set — strip 8–10 mm, push in. The auxiliary switch is present but no auxiliary contacts are built into the base unit; if you need a signal contact, order a separate auxiliary switch block.

Breaking capacity — where it holds

Rated short-circuit breaking capacity drops with voltage: 100 kA at 240 V and 400 V AC, then 3 kA at 500 V, and 2 kA at 690 V. The rated insulation voltage is 690 V, so the breaker is physically rated for 690 V systems — but the interrupting rating at that voltage is only 2 kA. In a 480 V panel you get the full 100 kA; at 600 V you're down to 3 kA. Check your available fault current at the point of installation before committing the BOM line.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-1EA20-ZW98?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Will 3RV1011-1EA20-ZW98 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?

Both are 3-pole SIRIUS breakers on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. The difference is in the trip rating and breaking capacity — verify your motor FLA and available fault current against the 3RV1011-1EA20-ZW98's 4 A continuous and 100 kA at 400 V before swapping.

What is 3RV1011-1EA20-ZW98's listed depth (81 mm) on this component line?

The depth is 81 mm. That's the body dimension; add clearance for any front-mounted operator or auxiliary switch block if used.

What is 3RV1011-1EA20-ZW98's listed solid (2x (0.25... 2.5 mm²)) on this component line?

The spring terminals accept two solid conductors per pole, each 0.25 to 2.5 mm². For finely stranded wire with ferrule, the range is 0.25 to 1.5 mm².

MPN
3RV1011-1EA20-ZW98