Siemens 3RV1011-1EA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1EA25 SIRIUS Motor Circuit Breaker, 4 A, Cla

MPN3RV1011-1EA25

Siemens SIRIUS 3RV1011-1EA25 motor protection circuit breaker, 4 A continuous current, Class 10 trip, spring-loaded terminals, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1EA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1EA25 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1EA25 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1EA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1EA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-1EA25 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1EA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1EA25 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 4 A, Class 10

The spring-loaded terminals on the main circuit accept 0.25 to 2.5 mm² solid or stranded wire (24 to 14 AWG), which means no screwdriver torque check during commissioning; just strip, insert, and pull to confirm the clamp has bit.

At 690 V the breaking capacity drops to 2 kA, so if the panel is on a 690 V IT system the fault current must be verified against that lower figure.

For a maintenance-spares purchaser holding a legacy cabinet full of SIRIUS 3RV breakers, this unit is a direct drop-in replacement that keeps the spare count current without re-coordination studies.

Depth is 81 mm and height is 90 mm. IP20 on the front face means the live terminals are finger-safe once installed; the panel builder still needs a cover over the rail if the cabinet is open to unskilled access.

Frequently asked questions

What wire sizes does the spring-loaded terminal accept?

The spring-loaded terminals on the main circuit accept 0.25 to 2.5 mm² solid or stranded wire, equivalent to 24 to 14 AWG.

Does 3RV1011-1EA25 include phase failure detection?

Yes, phase failure detection is built in, so the breaker will trip on an unbalanced condition from a single-phased motor.

MPN
3RV1011-1EA25