Siemens 3RV1011-1FA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1FA25 SIRIUS Motor Protection Circuit Breake

MPN3RV1011-1FA25

Siemens SIRIUS 3RV1011-1FA25 motor protection circuit breaker, 5 A continuous, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, current production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1FA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1FA25 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1FA25 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1FA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1FA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-1FA25 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1FA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1FA25 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-1FA25 is a SIRIUS motor protection circuit breaker rated for 5 A continuous current with a Class 10 trip characteristic, designed to protect three-phase induction motors up to 1.5 kW at 400 V AC. Its breaking capacity reaches 100 kA at 240 V and 400 V AC, dropping to 3 kA at 500 V and 2 kA at 690 V — meaning it can handle high fault currents on low-voltage distribution but needs coordination upstream at higher voltages.

Depth is 81 mm, height 90 mm — the 81 mm depth is worth noting for shallow enclosures where cable bend radius behind the breaker is tight. Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or stranded conductors (AWG 24...14), so no screw torque verification needed during commissioning.

Environmental and mechanical margins

Shock rated at 25 g for 11 ms. Main contacts specified for 100,000 mechanical operations.

Frequently asked questions

Will 3RV1011-1FA25 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Both share the same SIRIUS 3RV1 family footprint — 45 mm width, DIN rail mount, same terminal style — so mechanical fit is identical, but verify the trip current and breaking capacity differences between the two order codes before substituting.

What is 3RV1011-1FA25's listed depth?

The depth is 81 mm, which matters for shallow enclosures where cable bend radius behind the breaker is tight.