Skip to main content
Siemens 3RV1011-1GA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1GA20 SIRIUS Motor Protection Circuit Breake

MPN3RV1011-1GA20

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1GA20, 6.3 A rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, screw and snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1GA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1GA20 — Electrical
ParameterValue
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1GA20 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1GA20 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0
3RV1011-1GA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (24 ... 14)
3RV1011-1GA20 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany
3RV1011-1GA20 — Environmental
ParameterValue
Max. installation altitude2 000 m
3RV1011-1GA20 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-1GA20 is a SIRIUS motor protection circuit breaker rated for 6.3 A continuous current, with a Trip Class 10 characteristic that clears overloads before the motor insulation degrades — essential for standard three-phase induction motors up to 2.2 kW at 400 V.

The spring-loaded terminals on the main and auxiliary circuits accept 2x (0.25 to 2.5 mm²) solid or finely stranded wire, or 2x (24 to 14 AWG). No backwards clearance needed — zero mm behind the unit — so it fits tight against the backplane. Width is 45 mm, height 90 mm, depth 81 mm. Any mounting position is allowed.

Breaking capacity and environment

Breaking capacity varies with voltage: 100 kA at 240 V and 400 V AC, then drops to 3 kA at 500 V and 2 kA at 690 V. Front-side IP20 protection and finger-safe touch protection meet standard panel safety requirements. Surge voltage resistance rated at 6000 V.

Frequently asked questions

What is the breaking capacity of the 3RV1011-1GA20 at 400 V?

100 kA at 400 V AC, which allows it to handle high-fault-current panels without cascading upstream breakers.

Will the 3RV1011-1GA20 drop into a panel specified for the 3RV1011-1HA10?

Both are 45 mm wide SIRIUS motor protection breakers with the same DIN rail footprint and spring-loaded terminals, so they share the same mounting and wiring pattern — no rewiring needed for the panel layout.

What compliance documentation does the 3RV1011-1GA20 carry?

RoHS and REACH compliance with a substance prohibition date of 01.01.2013. The part also carries IP20 front protection and finger-safe touch protection.

Where can I buy the 3RV1011-1GA20 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN