Siemens 3RV1011-1GA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1GA25 SIRIUS Motor Protection Circuit Breake

MPN3RV1011-1GA25

Siemens SIRIUS motor-protective circuit breaker, 3RV1011-1GA25, 6.3 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, screw and snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1GA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1GA25 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV1011-1GA25 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo

Endurance & Switching

3RV1011-1GA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV1011-1GA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)

Mechanical

3RV1011-1GA25 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany

Environmental

3RV1011-1GA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C

Specifications

3RV1011-1GA25 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV1011-1GA25 is a SIRIUS motor-protective circuit breaker rated for 6.3 A continuous current with a CLASS 10 trip curve — meaning it trips within 10 seconds at 7.2× the set current, fast enough to protect standard induction motors from locked-rotor damage without nuisance tripping on normal starts.

Breaking capacity and fault clearing

Rated breaking capacity hits 100 kA at 240 V AC and 400 V AC, dropping to 3 kA at 500 V AC and 2 kA at 690 V AC. That 100 kA figure at 400 V means this breaker can safely interrupt a high-fault-current bolted short on a 400 V line without upstream fuses needing to coordinate — a real time-saver in panel design where the available fault current is high.

Termination and mounting

Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or 2x (24... 14 AWG) stranded — no screw torque to check, just strip and push. Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022, and the 45 mm width means it takes up a single modular slot. Any mounting position is allowed, and the front face carries IP20 finger protection.

Lifecycle and sourcing

Listed as current production — no phase-out or last-time-buy notice. Sourced and quoted to order against an RFQ through independent distribution.

Environmental and mechanical limits

Operates from -20 to +60 °C; stores or ships from -50 to +80 °C. Shock rated at 25 g / 11 ms, so it holds up in transport and moderate vibration environments. Altitude limit is 2 000 m without derating.

Frequently asked questions

Will 3RV1011-1GA25 drop into a panel specified around 3RV1011-1AA15 without rewiring?

Both are 45 mm wide SIRIUS motor-protective breakers with the same DIN rail footprint and spring-loaded terminals, so mechanical fit and wiring are identical. The key difference is the current rating: the 1GA25 is set at 6.3 A continuous, while the 1AA15 is rated lower — verify the motor FLA matches the breaker's setting range before swapping.

MPN
3RV1011-1GA25