Skip to main content
Siemens 3RV1011-1HA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1HA10-ZI45 SIRIUS Motor Protection Circuit B

MPN3RV1011-1HA10-ZI45

Siemens SIRIUS 3RV1011-1HA10-ZI45, motor protection circuit breaker, size S00, CLASS 10, adjustable overload release 5.5...8 A, instantaneous short-circuit trip 104 A, screw terminals, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1HA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1HA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1011-1HA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10
3RV1011-1HA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
3RV1011-1HA10-ZI45 — Mechanical
ParameterValue
Mounting positionany
3RV1011-1HA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection
3RV1011-1HA10-ZI45 — Other specifications
ParameterValue
Mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
At 400 V rated value3 000 W
Operating current rated value8 A
Adjustable pick-up value current of the current-dependent overload release5.5 ... 8 A

Product details

Its CLASS 10 trip class means the bimetal overload release will trip within 10 seconds at 7.2× the set current — the standard for standard-duty motor starting where the acceleration time stays under 10 seconds. The adjustable overload release spans 5.5 to 8 A, and the fixed magnetic short-circuit trip responds at 104 A.

The S00 footprint (45 mm wide) shares the same rail spacing as the SIRIUS contactor range, so the breaker and contactor can be ganged side-by-side without extra bus bars.

Rated operational current is 8 A at 400 V AC, corresponding to a motor rating of 3 000 W at 400 V. Power dissipation in hot operating state is 9.25 W total (3.1 W per pole). The breaker includes phase-failure detection and provides short-circuit protection without requiring separate fuses for most installations within its breaking capacity.

Frequently asked questions

What is the trip class of 3RV1011-1HA10-ZI45?

The trip class is CLASS 10, meaning the thermal overload release will trip within 10 seconds at 7.2× the set current.

What is the mounting type for this circuit breaker?

It mounts via screw and snap-on onto 35 mm standard mounting rail according to DIN EN 60715, in any mounting position.

Will 3RV1011-1HA10-ZI45 drop into a panel specified for 3RV1011-1HA10?

Yes, the base variant 3RV1011-1HA10 shares the same S00 footprint, 45 mm width, DIN-rail mounting, and screw-terminal arrangement. The -ZI45 suffix indicates a special version, but the mechanical fit and electrical ratings are identical.

How do I get pricing and availability for 3RV1011-1HA10-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV1011-1HA10-ZI45