Siemens 3RV1011-1HA10-ZW95 — Motor Protection Circuit Breakers (MPCB)

3RV1011-1HA10-ZW95 SIRIUS Motor Protection Circuit Breaker,

MPN3RV1011-1HA10-ZW95

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1HA10-ZW95, screw and snap-on mounting on 35 mm DIN rail, CLASS 10 trip, 100 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1HA10-ZW95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-1HA10-ZW95 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1011-1HA10-ZW95 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-1HA10-ZW95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV1011-1HA10-ZW95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV1011-1HA10-ZW95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV1011-1HA10-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV1011-1HA10-ZW95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and where it fits

The 3RV1011-1HA10-ZW95 is a Siemens SIRIUS motor protection circuit breaker — designed specifically for motor protection, not just branch-circuit overcurrent. It screws or snaps onto 35 mm DIN rail per DIN EN 60715, so it lands in any standard panel without special brackets. The ZW95 suffix is a special version identifier; the base mechanicals and ratings match the standard 3RV1011-1HA10 footprint. Width is 45 mm, depth is 75 mm, height is 90 mm — same slot as any 3RV10 frame, so it drops into an existing panel layout without re-drilling.

Breaking capacity and trip class — what they mean for the line

Rated short-circuit breaking capacity is 100 kA at 240 V, dropping to 13 kA at 400 V, 3 kA at 500 V, and 2 kA at 690 V. That 100 kA at 240 V means it can sit downstream of a transformer with high fault current without needing a current-limiting upstream breaker — useful in retrofit panels where the available fault current wasn't originally calculated tight. Trip Class 10 means it disconnects within 10 seconds at 7.2× the thermal setting. That's the standard for standard motor start profiles — not too fast to nuisance-trip on a normal start, fast enough to protect the motor winding on a locked rotor. Phase failure detection is built in — no separate phase-loss relay needed. If one phase drops, the breaker trips even if the current on the remaining phases stays below the overload threshold. That saves a control-wiring step and one DIN slot.

Mounting and wiring

Mounting position is any — vertical, horizontal, upside-down in a tight enclosure — the thermal and magnetic trip elements work the same. Screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) solid or stranded, or 2×(0.75…2.5 mm²). Main contact screws are M3. Clearance spacing: 20 mm above and below, 9 mm at the sides, zero forwards or backwards. That 9 mm side gap is tighter than some breakers — you can pack these on a DIN rail with minimal air between units, which matters when you're squeezing a motor control center into a compact footprint.

Frequently asked questions

Will 3RV1011-1HA10-ZW95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Yes — the ZW95 suffix is a special version identifier, but the dimensions (45 mm wide, 75 mm deep, 90 mm tall) and mounting method (screw and snap-on onto 35 mm DIN rail) are identical to the standard 3RV1011-1HA10. No panel rework or re-drilling needed.

MPN
3RV1011-1HA10-ZW95