Siemens 3RV1011-1HA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1HA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV1011-1HA10-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV1011-1HA10-ZX95, CLASS 10 trip, 45 mm wide, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1HA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1HA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1011-1HA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1HA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1HA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1HA10-ZX95 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV1011-1HA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1HA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

At 45 mm wide and 90 mm tall, it occupies a single standard modular slot, leaving room alongside contactors and overload relays in a dense panel layout.

At 690 V it still clears 2 kA, enough for many 690 V motor circuits in mining or marine gear. That prevents single-phasing damage on a motor that would otherwise try to run on two phases and burn up the winding. The gL/gG fuse backup ratings let you coordinate with upstream fuses: 80 A at 240 V, 63 A at 400 V, 40 A at 500 V and 690 V. That tells your panel designer what fuse size to spec ahead of this breaker to keep selective coordination.

Mounting position is any — vertical, horizontal, upside down — no derating needed for orientation. Screw-type terminals on the main circuit accept 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded copper. Terminal screws are M3. Clearance around the unit: 20 mm above and below, 9 mm to the side, zero in front or back — tight panel spacing works.

Environmental range and storage

Operates from -20 °C to +60 °C, with temperature compensation active across that entire span so the thermal trip curve stays accurate. Rated voltage range covers 20 V to 690 V, so it works on control voltages as low as 24 VAC/DC as well as standard 400 V and 690 V power circuits.

Frequently asked questions

Will 3RV1011-1HA10-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Yes — same 45 mm width, same screw and snap-on DIN rail mount, same terminal specs. The -ZX95 suffix indicates a special version but the mechanical footprint is identical.

What is the short-circuit breaking capacity at 400 V?

13 kA at 400 V, with a gL/gG fuse backup rating of 63 A at that voltage level.

Where can I buy 3RV1011-1HA10-ZX95 and get current pricing?

Sourced to order through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
3RV1011-1HA10-ZX95