MPN3RV1011-1JA15-0BA0
Active

Siemens SIRIUS 3RV1011-1JA15-0BA0, motor-protective circuit breaker, 10 A continuous, CLASS 10, 4 kW at 400 V, screw terminals, snap-on DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1JA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker

Electrical

3RV1011-1JA15-0BA0 — Electrical
ParameterValue
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1011-1JA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range7 ... 10 A
Instantaneous short-circuit trip current130 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV1011-1JA15-0BA0 — Endurance & Switching
ParameterValue
Auxiliary CO (changeover) contacts0

Connections

3RV1011-1JA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14)

Mechanical

3RV1011-1JA15-0BA0 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Mounting positionany

Environmental

3RV1011-1JA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Max. installation altitude2 000 m

Specifications

3RV1011-1JA15-0BA0 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor-protective circuit breaker for 4 kW loads

The Siemens 3RV1011-1JA15-0BA0 is a SIRIUS motor-protective circuit breaker rated for 10 A continuous current with CLASS 10 trip characteristic, sized for a 4 kW motor at 400 V AC. It combines a thermal overload release for sustained overcurrent and a magnetic short-circuit trip for fault clearing, with phase-failure detection built in. The 45 mm wide body snaps onto a 35 mm DIN rail per EN 50022 and accepts screw-type terminals for the main and auxiliary circuits.

Breaking capacity and coordination

Rated breaking capacity reaches 100 kA at 240 V AC, 50 kA at 400 V AC, 3 kA at 500 V AC, and 2 kA at 690 V AC. These figures define the fault current the device can safely interrupt at each voltage level — critical for selectivity studies and SCCR compliance in a panel. The 690 V maximum operating voltage (AC-3 duty) covers 480 V and 600 V class systems common in North American and IEC installations.

Auxiliary contact ratings

The transverse auxiliary switch is rated 1 A at 24 V, 0.5 A at 230 V, and 0.15 A at 60 V. These are the switching capacities for the control circuit — useful when sizing the contact load for a PLC input or relay coil. Terminal wiring accepts solid or stranded conductors: 2x 0.5…1.5 mm² or 2x 0.75…2.5 mm², with AWG 18…14 equivalents for the main contacts.

Mounting and environment

Mounts in any position via screw fixing or snap-on onto a 35 mm DIN rail. The 45 x 90 x 81 mm (W x H x D) footprint fits standard distribution board spacing — zero clearance required at the sides or rear. IP20 on the front protects against finger contact in a closed panel. Operating temperature range is -50 to +60 °C, storage and transport -50 to +80 °C. Shock rated 25g / 11 ms.

Frequently asked questions

Where can I buy 3RV1011-1JA15-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 3RV1011-1JA15-0BA0 drop into a panel specified for 3RV1011-1HA10?

Both are 45 mm wide SIRIUS motor-protective circuit breakers with the same DIN-rail mounting and screw-terminal pattern, so a panel designed for the 3RV1011-1HA10 will accept this unit without rewiring, provided the current rating and trip class match the application.

What is the breaking capacity at 400 V?

50 kA at 400 V AC.

What compliance documentation is available?

RoHS compliance is dated 01/01/2013. The design follows IEC/EN 60947 standards for motor-protective circuit breakers.

MPN