Siemens 3RV1011-1KA10-ZI45 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1KA10-ZI45 SIRIUS Motor Protection Circuit B

MPN3RV1011-1KA10-ZI45

Siemens SIRIUS, motor protection circuit breaker, 3RV1011-1KA10-ZI45, size S00, 12.5 A rated current, CLASS 10 trip, adjustable thermal overload 9-12.5 A, screw terminals, snap-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV1011-1KA10-ZI45 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV1011-1KA10-ZI45 — Electrical
ParameterValue
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV1011-1KA10-ZI45 — Protection & Tripping
ParameterValue
Trip classCLASS 10

Connections

3RV1011-1KA10-ZI45 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom

Mechanical

3RV1011-1KA10-ZI45 — Mechanical
ParameterValue
Mounting positionany

Specifications

3RV1011-1KA10-ZI45 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, size S00 — 12.5 A, CLASS 10

The Siemens SIRIUS 3RV1011-1KA10-ZI45 is a motor protection circuit breaker sized for the S00 frame, rated at 12.5 A operating current with an adjustable thermal overload release spanning 9 to 12.5 A. The CLASS 10 trip class means it will disconnect within 10 seconds at 600% of the set current — fast enough to protect standard induction motors during a stall or locked-rotor condition without nuisance tripping on normal starts. This breaker is designed for motor protection duty, combining a thermal overload element for sustained overcurrents and a magnetic short-circuit trip. The screw-type terminals on top and bottom accept solid or stranded copper conductors, and the unit mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. Mounting position is any — no derating needed for horizontal or vertical panel layouts.

DIN-rail integration and panel fit

The S00 frame measures 45 mm wide, 90 mm high, and 75 mm deep, with 20 mm clearance required above and below the unit and 9 mm at the sides — no extra space needed in front or behind. That keeps the footprint tight on a crowded DIN rail. The breaker snaps onto standard 35 mm rail and accepts screw-clamp wiring; the Pozidriv #2 screw terminals torque to 0.8–1.2 N·m for both main and auxiliary contacts. At full load the breaker dissipates 9.25 W total (3.1 W per pole) in the hot operating state — a factor to check when calculating enclosure heat rise in a sealed panel.

Frequently asked questions

What is the adjustable overload range on this breaker?

The thermal overload release adjusts from 9 A to 12.5 A. The magnetic short-circuit trip responds at 156 A (fixed, not adjustable).

Will 3RV1011-1KA10-ZI45 drop into a panel specified for 3RV1011-1HA10?

The two share the same S00 frame, DIN-rail mount, screw terminals, and clearance dimensions (20 mm up/down, 9 mm sides, 0 mm front/back). The difference is the current range: the 1HA10 adjusts 5.5–8 A while this 1KA10 adjusts 9–12.5 A. If the load current falls within 9–12.5 A, the 1KA10 is a direct mechanical fit — no rewiring or panel modification needed.

Where can I buy 3RV1011-1KA10-ZI45?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Contact our desk for a current quote — availability and pricing are confirmed at that time.