Skip to main content
Siemens 3RV1011-1KA20-ZW98 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1KA20-ZW98 SIRIUS Motor Circuit Breaker, 12

MPN3RV1011-1KA20-ZW98

Siemens SIRIUS 3RV1011-1KA20-ZW98, motor-protective circuit breaker, 12 A, 5.5 kW at 400 V, Class 10, spring-loaded terminals, screw and snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1KA20-ZW98 — Identification
ParameterValue
SeriesSIRIUS
Product designationcircuit breaker
3RV1011-1KA20-ZW98 — Electrical
ParameterValue
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated impulse withstand voltage (Uimp)6 000 V
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV1011-1KA20-ZW98 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)50 kA
Breaking capacity at 500 V (AC)3 kA
Breaking capacity at 690 V (AC)2 kA
Phase-failure detectionYes
Ground-fault detectionNo
3RV1011-1KA20-ZW98 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
3RV1011-1KA20-ZW98 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementfront side
Conductor cross-section, finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RV1011-1KA20-ZW98 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth81 mm
Mounting positionany
3RV1011-1KA20-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
3RV1011-1KA20-ZW98 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens SIRIUS 3RV1011-1KA20-ZW98 is a motor-protective circuit breaker rated for 12 A continuous current and 5.5 kW at 400 V AC-3. It's built for the panel — screw and snap-on onto 35 mm DIN rail per EN 50022, and the spring-loaded terminals on the main circuit accept 2x (0.25…2.5 mm²) solid or 2x (0.25…1.5 mm²) finely stranded with ferrules. Class 10 trip protects standard induction motors during stall or overload, and the phase failure detection catches a lost phase before the winding cooks.

At 240 V it jumps to 100 kA; at 500 V it drops to 3 kA, and at 690 V to 2 kA. The 6 000 V surge voltage resistance (rated impulse withstand) gives selectivity headroom for the downstream contactor.

Mounting position any — fine for horizontal or vertical DIN-rail layouts. IP20 on the front; the 45 mm width and 81 mm depth fit standard enclosure gland plates. Shock rated at 25g / 11 ms — shrugs off the vibration you get near crushers and conveyors.

Power dissipation

Dissipates 9.25 W total in hot operating state at rated current, 3.1 W per pole.

Frequently asked questions

Where can I buy 3RV1011-1KA20-ZW98 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the closest functional second-source for 3RV1011-1KA20-ZW98?

The 3RV1011-1HA10 is a peer in the same SIRIUS family but with a different current rating and trip class; it will not drop into the same BOM line without verifying the motor FLA and coordination study.

Will 3RV1011-1KA20-ZW98 drop into a panel specified around 3RV1011-1HA10 without rewiring?

Both share the same 45 mm width, DIN-rail mounting, and spring-loaded terminal format, so the mechanical fit is identical — but the 3RV1011-1HA10 has a different current rating and trip characteristic, so the overload protection settings must be re-verified.

MPN
3RV1011-1KA20-ZW98